Purpose This study aimed to inform office employees about the negative health effects of high carbon dioxide (CO2) levels and the preference for wind catchers as a filtration in building assessments during winter. Design/methodology/approach The study statistically analyzed temperature, relative humidity (RH), CO2, using correlation, regression and employees’ subjective comfort votes. Three standards given in the Center for Built Environment were evaluated for thermal sensation in offices. Findings Compliance with American Society of Heating, Refrigerating Engineers (ASHRAE) 55 and adaptive standards was achieved for thermal sensation of “electric heater” (Predicted Mean Vote −0.3, Predicted Percentage of Dissatisfied 6.90%), “wind chimney and gas heater” (80% comfortable) and “no heater” (80% to 90% comfortable). However, the CO2 concentration in offices was 2.7-4.7 times higher than the World Health Organization recommendations. Research limitations/implications The study is limited to an exploratory analysis of environmental monitoring and employees’ responses toward the impact of wind catchers in building evaluation across three heating modes. Practical implications Employees can predict indoor comfort for passive, active heating and building controls during winter, reducing office syndrome. Increased awareness of wind catchers, “tower and scoop”, suggested that stakeholders use it as an energy-efficient solution in offices. Social implications The study aims to establish building practices to ensure compliance and promote the use of wind catchers’ natural ventilation. Originality/value The relationship between temperature, RH, CO2 concentration and employee satisfaction in “electric, gas, and no heater” scenarios were investigated to ensure standard compliance during the building evaluation.

Authors

Institutions

Publication Details

Journal
Facilities
Published
2026-01-15
DOI
https://doi.org/10.1108/f-02-2025-0038
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An exploratory study of office building evaluation for the standard compliance and wind catcher preference during winter in subtropics

Mohd Firdaus Bin Abas, Kamarul Arifin Ahmad, Mohd Fairuz Shahidan, A Rehman Khalid et al.
Facilities
Indoor Air Quality and Microbial Exposure
article

An exploratory study of office building evaluation for the standard compliance and wind catcher preference during winter in subtropics

Mohd Firdaus Bin Abas, Kamarul Arifin Ahmad, Mohd Fairuz Shahidan, A Rehman Khalid, Nur Dalilah Binti Dahlan
article en

Abstract

Purpose This study aimed to inform office employees about the negative health effects of high carbon dioxide (CO2) levels and the preference for wind catchers as a filtration in building assessments during winter. Design/methodology/approach The study statistically analyzed temperature, relative humidity (RH), CO2, using correlation, regression and employees’ subjective comfort votes. Three standards given in the Center for Built Environment were evaluated for thermal sensation in offices. Findings Compliance with American Society of Heating, Refrigerating Engineers (ASHRAE) 55 and adaptive standards was achieved for thermal sensation of “electric heater” (Predicted Mean Vote −0.3, Predicted Percentage of Dissatisfied 6.90%), “wind chimney and gas heater” (80% comfortable) and “no heater” (80% to 90% comfortable). However, the CO2 concentration in offices was 2.7-4.7 times higher than the World Health Organization recommendations. Research limitations/implications The study is limited to an exploratory analysis of environmental monitoring and employees’ responses toward the impact of wind catchers in building evaluation across three heating modes. Practical implications Employees can predict indoor comfort for passive, active heating and building controls during winter, reducing office syndrome. Increased awareness of wind catchers, “tower and scoop”, suggested that stakeholders use it as an energy-efficient solution in offices. Social implications The study aims to establish building practices to ensure compliance and promote the use of wind catchers’ natural ventilation. Originality/value The relationship between temperature, RH, CO2 concentration and employee satisfaction in “electric, gas, and no heater” scenarios were investigated to ensure standard compliance during the building evaluation.

FacilitiesVol. 44(3-4)
Universiti Putra Malaysia (MY), Tun Hussein Onn University of Malaysia (MY)
Affordable and clean energy
Openalex Percentile: Top 89%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.