Approaches to assessing completeness of colorectal polyp resections in clinical practice: a systematic scoping review

Protocols for standardized assessment of complete colorectal polyp resection are lacking, contributing to divergent quality standards and hindering reliable comparison of incomplete resection rates (IRRs) across resection devices, techniques, endoscopists, and institutions. We reviewed available methods to inform the development of such protocols.We systematically searched MEDLINE, Embase, Web of Science, and Cochrane Library databases from inception to 30 July 2024. Studies describing the use or validation of methods for assessing completeness of polyp resection were included. Studies using recurrence detected at follow-up or histopathological resection specimen margin assessment as outcome measures were excluded, unless used as reference standards for evaluation of other methods.45 eligible studies were identified. Methods for assisting in visual confirmation of complete resection included image enhancement techniques (6 studies), artificial intelligence (1 study), and resection defect diameter (1 study). Methods for measuring IRRs based on a histopathological reference standard involved biopsy sampling (29 studies) and extended margin resection (8 studies). IRR measurement protocols differed in terms of factors such as location and number of biopsies (1-8) and widths of extended resections (1-3 mm). IRRs >10% were observed for all polyp size categories and almost all resection techniques, with considerable variability in IRRs reported across studies (biopsy sampling 0-24.2%; extended resection 0-61.1%).Different methods are available to assist in visual confirmation of complete resection and measuring IRRs, with considerable variability in their application, highlighting the need for standardized assessment of complete colorectal polyp resection.

Authors

Institutions

Publication Details

Journal
Endoscopy
Published
2026-01-14
DOI
https://doi.org/10.1055/a-2783-3897
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Approaches to assessing completeness of colorectal polyp resections in clinical practice: a systematic scoping review

Manon van der Vlugt, Silpa Yarra, Evelien Dekker, Aasma Shaukat et al.
Endoscopy
Colorectal Cancer Screening and Detection
article

Approaches to assessing completeness of colorectal polyp resections in clinical practice: a systematic scoping review

Manon van der Vlugt, Silpa Yarra, Evelien Dekker, Aasma Shaukat, Querijn N.E. van Bokhorst, Heiko Pohl
article en

Abstract

Protocols for standardized assessment of complete colorectal polyp resection are lacking, contributing to divergent quality standards and hindering reliable comparison of incomplete resection rates (IRRs) across resection devices, techniques, endoscopists, and institutions. We reviewed available methods to inform the development of such protocols.We systematically searched MEDLINE, Embase, Web of Science, and Cochrane Library databases from inception to 30 July 2024. Studies describing the use or validation of methods for assessing completeness of polyp resection were included. Studies using recurrence detected at follow-up or histopathological resection specimen margin assessment as outcome measures were excluded, unless used as reference standards for evaluation of other methods.45 eligible studies were identified. Methods for assisting in visual confirmation of complete resection included image enhancement techniques (6 studies), artificial intelligence (1 study), and resection defect diameter (1 study). Methods for measuring IRRs based on a histopathological reference standard involved biopsy sampling (29 studies) and extended margin resection (8 studies). IRR measurement protocols differed in terms of factors such as location and number of biopsies (1-8) and widths of extended resections (1-3 mm). IRRs >10% were observed for all polyp size categories and almost all resection techniques, with considerable variability in IRRs reported across studies (biopsy sampling 0-24.2%; extended resection 0-61.1%).Different methods are available to assist in visual confirmation of complete resection and measuring IRRs, with considerable variability in their application, highlighting the need for standardized assessment of complete colorectal polyp resection.

Endoscopy
White River Junction VA Medical Center (US), Amsterdam University Medical Centers (NL), Cancer Center Amsterdam (NL), New York University (US)
Openalex Percentile: Top 87%
Colorectal Cancer Screening and Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.