Characterization of Fluorophore-Quencher Pairs for Distance-Dependent Molecular Sensing in Photoacoustic Imaging

Photoacoustic imaging coupled with molecularly responsive sensors is emerging as an attractive alternative to traditional fluorescence sensors in the deep-tissue quantification of specific molecular analytes. The range of fluorophore/quencher pairs suitable for this approach remains limited. In response, here we have systematically evaluated a set of near-infrared fluorophores for their ability to support photoacoustic imaging coupled with molecularly responsive sensors. Specifically, we have used a DNA molecular ruler to precisely vary the fluorophore-quencher distance while monitoring the absorbance, fluorescence, and photoacoustic spectra of five near-infrared fluorophores. Our results confirm previous findings identifying IRDye 800CW as a strong candidate and further establish ICG and IRDye 800 as highly promising fluorophores for responsive photoacoustic applications. We also demonstrated robust tissue penetration and preserved distance-dependent behavior under biologically relevant conditions, with ICG achieving the highest signal-to-noise ratio and the most predictable quenching response. These findings expand the palette of near-infrared probes and provide a clear framework for designing next-generation photoacoustic molecular sensors for in vivo imaging.

Authors

Institutions

Publication Details

Journal
Chemical & Biomedical Imaging
Published
2026-01-15
DOI
https://doi.org/10.1021/cbmi.5c00178
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of Fluorophore-Quencher Pairs for Distance-Dependent Molecular Sensing in Photoacoustic Imaging

Simon R. Corrie, Toby D. M. Bell, Salma Sultana Tunny, Kevin W. Plaxco et al.
Chemical & Biomedical Imaging
Photoacoustic and Ultrasonic Imaging
article

Characterization of Fluorophore-Quencher Pairs for Distance-Dependent Molecular Sensing in Photoacoustic Imaging

Simon R. Corrie, Toby D. M. Bell, Salma Sultana Tunny, Kevin W. Plaxco, Ekaterina Salimova, Christoph E. Hagemeyer
article en

Abstract

Photoacoustic imaging coupled with molecularly responsive sensors is emerging as an attractive alternative to traditional fluorescence sensors in the deep-tissue quantification of specific molecular analytes. The range of fluorophore/quencher pairs suitable for this approach remains limited. In response, here we have systematically evaluated a set of near-infrared fluorophores for their ability to support photoacoustic imaging coupled with molecularly responsive sensors. Specifically, we have used a DNA molecular ruler to precisely vary the fluorophore-quencher distance while monitoring the absorbance, fluorescence, and photoacoustic spectra of five near-infrared fluorophores. Our results confirm previous findings identifying IRDye 800CW as a strong candidate and further establish ICG and IRDye 800 as highly promising fluorophores for responsive photoacoustic applications. We also demonstrated robust tissue penetration and preserved distance-dependent behavior under biologically relevant conditions, with ICG achieving the highest signal-to-noise ratio and the most predictable quenching response. These findings expand the palette of near-infrared probes and provide a clear framework for designing next-generation photoacoustic molecular sensors for in vivo imaging.

Chemical & Biomedical Imaging
Diabetes Australia (AU), Australian Regenerative Medicine Institute (AU), University of California System (US), Monash Health (AU), Monash University (AU)
Openalex Percentile: Top 88%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of Fluorophore-Quencher Pairs for Distance-Dependent Molecular Sensing in Photoacoustic Imaging — Simon R. Corrie, Toby D. M. Bell, et al. · Chemical & Biomedical Imaging (2026) | TGRS Research Map | TGRS