Design, Optimization, and Experimental Validation of a 3D-Printed Tympanostomy Tube Using Neural Networks and Simulated Annealing

Abstract This study presents a data-driven framework for optimizing tympanostomy tube design to enhance fluid drainage efficiency and reduce drainage duration. Current commercial tubes often show inconsistent performance due to suboptimal fluid dynamics. The proposed approach integrates experimental data, neural network modeling, and computational optimization to refine key geometric and operational parameters. A total of 1080 experiments were conducted using 15 geometries, six materials (e.g., silicone, titanium), and two fluid types (water and Ciprodex). A neural network with two hidden layers (10 neurons each), trained via the Levenberg-Marquardt algorithm, predicted drainage outcomes of exiting droplet count and drainage duration with high accuracy (coefficient of determination (R2) = 0.80, root-mean-square error (RMSE) = 0.62 for droplet count; R2 = 0.92, RMSE = 2.19 for duration). Sensitivity analysis identified tube length, diameter, and inlet droplet count as the most influential parameters, while material and fluid type had limited impact. Simulated annealing (SA) (2800 iterations) was applied for multi-objective optimization, targeting maximal drainage and minimal time. Optimal designs featured increased length (1.27–1.4 mm), reduced diameter (<0.76 mm), and controlled inlet droplets (1 droplet). Experimental validation using three-dimensionally (3D)-printed PETG + PTFE prototypes confirmed model predictions, with drainage durations deviating by 7.5–10.5% and outlet droplet counts differing by at most one per trial. These results demonstrate the predictive accuracy and robustness of computational models, establishing a scalable methodology for integrating machine learning, global optimization, and low-cost prototyping in medical device design, supporting future in vivo studies and clinical translation.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2026-01-14
DOI
https://doi.org/10.1115/1.4070895
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design, Optimization, and Experimental Validation of a 3D-Printed Tympanostomy Tube Using Neural Networks and Simulated Annealing

Anita Jeyakumar, Motaz Hassan, Ajay Mahajan
Journal of Medical Devices
Ear Surgery and Otitis Media
article

Design, Optimization, and Experimental Validation of a 3D-Printed Tympanostomy Tube Using Neural Networks and Simulated Annealing

Anita Jeyakumar, Motaz Hassan, Ajay Mahajan
article en

Abstract

Abstract This study presents a data-driven framework for optimizing tympanostomy tube design to enhance fluid drainage efficiency and reduce drainage duration. Current commercial tubes often show inconsistent performance due to suboptimal fluid dynamics. The proposed approach integrates experimental data, neural network modeling, and computational optimization to refine key geometric and operational parameters. A total of 1080 experiments were conducted using 15 geometries, six materials (e.g., silicone, titanium), and two fluid types (water and Ciprodex). A neural network with two hidden layers (10 neurons each), trained via the Levenberg-Marquardt algorithm, predicted drainage outcomes of exiting droplet count and drainage duration with high accuracy (coefficient of determination (R2) = 0.80, root-mean-square error (RMSE) = 0.62 for droplet count; R2 = 0.92, RMSE = 2.19 for duration). Sensitivity analysis identified tube length, diameter, and inlet droplet count as the most influential parameters, while material and fluid type had limited impact. Simulated annealing (SA) (2800 iterations) was applied for multi-objective optimization, targeting maximal drainage and minimal time. Optimal designs featured increased length (1.27–1.4 mm), reduced diameter (<0.76 mm), and controlled inlet droplets (1 droplet). Experimental validation using three-dimensionally (3D)-printed PETG + PTFE prototypes confirmed model predictions, with drainage durations deviating by 7.5–10.5% and outlet droplet counts differing by at most one per trial. These results demonstrate the predictive accuracy and robustness of computational models, establishing a scalable methodology for integrating machine learning, global optimization, and low-cost prototyping in medical device design, supporting future in vivo studies and clinical translation.

Journal of Medical DevicesVol. 20(3)
University of Akron (US), Akron Polymer Systems (United States) (US), Northeast Ohio Medical University (US)
Clean water and sanitation
Openalex Percentile: Top 88%
Ear Surgery and Otitis Media
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.