Learning-Based Hybrid Needle Tip Tracking and Visualization Framework for Robotic Ultrasound-Guided Interventions

Ultrasound (US)-guided needle-based interventions have been extensively employed in clinical practice for biopsies, regional anesthesia, and tumor ablation, considering the advantages of real-time imaging, portability, and non-ionizing radiation. Precise localization and tracking of the needle tip are critical for ensuring the successful needle placement while minimizing the risk of injury to surrounding anatomical structures. However, achieving real-time and reliable needle tip tracking remains challenging due to the inherent properties of US images, such as low spatial resolution, speckle noise, and imaging artifacts that obscure the needle tip. This study proposes a hybrid learning-based framework for accurately and robustly localizing the needle tip within the US image plane during robot-assisted interventional procedures. The framework comprises a dual-branch template matching-based detection module, a Convolutional Neural Network (CNN)-based detection module, and a “dynamic template selection and updating" mechanism to enhance overall tracking performance. Additionally, to recover the needle tip invisibility caused by unanticipated movements, an active exploration strategy based on a Gaussian Process (GP) model and Bayesian Optimization (BO) is proposed for efficient and accurate robotic US probe pose adjustment. The effectiveness of the proposed method for needle tip tracking performance has been evaluated through a series of experiments conducted on ex vivo porcine liver samples under varying insertion angles and velocities. Experimental results demonstrate that the proposed framework achieves a maximum median localization error of 1.17 mm and an Interquartile Range (IQR) of 1.28 mm across all test conditions. Furthermore, in scenarios requiring needle tip visibility recovery, the proposed BO-based strategy achieved a median localization error of 1.52 mm and an IQR of 0.95 mm.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Robotics and Bionics
Published
2026-01-14
DOI
https://doi.org/10.1109/tmrb.2026.3654277
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Learning-Based Hybrid Needle Tip Tracking and Visualization Framework for Robotic Ultrasound-Guided Interventions

Runing Xiao, Alberto Redaelli, Junling Fu, Zijian Cai et al.
IEEE Transactions on Medical Robotics and Bionics
Soft Robotics and Applications
article

Learning-Based Hybrid Needle Tip Tracking and Visualization Framework for Robotic Ultrasound-Guided Interventions

Runing Xiao, Alberto Redaelli, Junling Fu, Zijian Cai, Elena De Momi, Giancarlo Ferrigno
article en

Abstract

Ultrasound (US)-guided needle-based interventions have been extensively employed in clinical practice for biopsies, regional anesthesia, and tumor ablation, considering the advantages of real-time imaging, portability, and non-ionizing radiation. Precise localization and tracking of the needle tip are critical for ensuring the successful needle placement while minimizing the risk of injury to surrounding anatomical structures. However, achieving real-time and reliable needle tip tracking remains challenging due to the inherent properties of US images, such as low spatial resolution, speckle noise, and imaging artifacts that obscure the needle tip. This study proposes a hybrid learning-based framework for accurately and robustly localizing the needle tip within the US image plane during robot-assisted interventional procedures. The framework comprises a dual-branch template matching-based detection module, a Convolutional Neural Network (CNN)-based detection module, and a “dynamic template selection and updating" mechanism to enhance overall tracking performance. Additionally, to recover the needle tip invisibility caused by unanticipated movements, an active exploration strategy based on a Gaussian Process (GP) model and Bayesian Optimization (BO) is proposed for efficient and accurate robotic US probe pose adjustment. The effectiveness of the proposed method for needle tip tracking performance has been evaluated through a series of experiments conducted on ex vivo porcine liver samples under varying insertion angles and velocities. Experimental results demonstrate that the proposed framework achieves a maximum median localization error of 1.17 mm and an Interquartile Range (IQR) of 1.28 mm across all test conditions. Furthermore, in scenarios requiring needle tip visibility recovery, the proposed BO-based strategy achieved a median localization error of 1.52 mm and an IQR of 0.95 mm.

IEEE Transactions on Medical Robotics and BionicsVol. 8(1)
Politecnico di Milano (IT)
Openalex Percentile: Top 88%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.