Ultrasensitive Detection of Cardiac Troponin I via CRISPR/Cas12a-Mediated Liposomal Amplification Coupled with Electrospray Ionization Mass Spectrometry

Direct quantitative analysis of low-abundance protein biomarkers by electrospray ionization mass spectrometry (ESI-MS) remains challenging due to poor ionization efficiency and matrix interferences. Herein, we report an ultrasensitive analytical platform, termed CRISPR/Cas12a-mediated liposomal amplification coupled with electrospray ionization mass spectrometry (CMLA-MS), that overcomes this limitation by integrating CRISPR/Cas12a-mediated dual-cascade signal amplification with an ESI-MS readout. The strategy converts the detection of poorly ionizable protein molecules into the quantification of numerous, highly ionizable small-molecule reporters: proteins trigger Cas12a trans-cleavage (first amplification), which subsequently cleaves single-stranded DNA (ssDNA) probes anchored to signal-loaded liposomes, causing the burst release of thousands of MS-detectable reporters (second, physical amplification). This dual-amplification strategy enabled an exceptionally low limit of detection (LOD) of 10.8 fg/mL, and the method successfully quantified cardiac troponin I (cTnI) in clinical serum samples with high recoveries (90.3-101.6%).

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-14
DOI
https://doi.org/10.1021/acs.analchem.5c05804
Primary Topic
CRISPR and Genetic Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive Detection of Cardiac Troponin I via CRISPR/Cas12a-Mediated Liposomal Amplification Coupled with Electrospray Ionization Mass Spectrometry

X. Chen, Chaoting Shi, Yang Wu, Zhuolin Jin et al.
Analytical Chemistry
CRISPR and Genetic Engineering
article

Ultrasensitive Detection of Cardiac Troponin I via CRISPR/Cas12a-Mediated Liposomal Amplification Coupled with Electrospray Ionization Mass Spectrometry

X. Chen, Chaoting Shi, Yang Wu, Zhuolin Jin, Bing Xia, Chunxiang Mao, Yan Zhou, Yuanji Gao
article en

Abstract

Direct quantitative analysis of low-abundance protein biomarkers by electrospray ionization mass spectrometry (ESI-MS) remains challenging due to poor ionization efficiency and matrix interferences. Herein, we report an ultrasensitive analytical platform, termed CRISPR/Cas12a-mediated liposomal amplification coupled with electrospray ionization mass spectrometry (CMLA-MS), that overcomes this limitation by integrating CRISPR/Cas12a-mediated dual-cascade signal amplification with an ESI-MS readout. The strategy converts the detection of poorly ionizable protein molecules into the quantification of numerous, highly ionizable small-molecule reporters: proteins trigger Cas12a trans-cleavage (first amplification), which subsequently cleaves single-stranded DNA (ssDNA) probes anchored to signal-loaded liposomes, causing the burst release of thousands of MS-detectable reporters (second, physical amplification). This dual-amplification strategy enabled an exceptionally low limit of detection (LOD) of 10.8 fg/mL, and the method successfully quantified cardiac troponin I (cTnI) in clinical serum samples with high recoveries (90.3-101.6%).

Analytical ChemistryVol. 98(3)
Chinese Academy of Sciences (CN), Chengdu Institute of Biology (CN), University of Chinese Academy of Sciences (CN), Chengdu University of Traditional Chinese Medicine (CN), Sichuan Normal University (CN)
Openalex Percentile: Top 88%
CRISPR and Genetic Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ultrasensitive Detection of Cardiac Troponin I via CRISPR/Cas12a-Mediated Liposomal Amplification Coupled with Electrospray Ionization Mass Spectrometry — X. Chen, Chaoting Shi, et al. · Analytical Chemistry (2026) | TGRS Research Map | TGRS