3.3V Sub-nA Voltage Gap Readout Circuit for Memristive Biosensing in Silicon Nanowire

This paper proposes a sub-nanoampere readout circuit designed for fast and precise detection with silicon nanowire (SiNW) memristive biosensors via voltage gap measurement. Compared to traditional solutions, the proposed circuit, completed in 65 nm bulk CMOS process, significantly enhances sensitivity to the picoampere range and reduces measurement time from several minutes to one second. Comprehensive performance evaluation has been performed by considering SiNW models with different crossing behavior, including post-layout extraction (PEX) simulations. Accuracy of up to $20-30 \mathrm{mV}$ can be achieved on a particular prescaler configuration, which confirms circuit’s suitability for high-speed biosensing, real-time diagnostics and scalable integration into large sensor arrays.

Authors

Institutions

Publication Details

Published
2025-10-16
DOI
https://doi.org/10.1109/biocas67066.2025.00113
Primary Topic
Nanowire Synthesis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3.3V Sub-nA Voltage Gap Readout Circuit for Memristive Biosensing in Silicon Nanowire

Gian Luca Barbruni, Pavel Horský, Dmitrii Semenov, Sandro Carrara et al.
Nanowire Synthesis and Applications
article

3.3V Sub-nA Voltage Gap Readout Circuit for Memristive Biosensing in Silicon Nanowire

Gian Luca Barbruni, Pavel Horský, Dmitrii Semenov, Sandro Carrara, Kapil Bhardwaj
article en

Abstract

This paper proposes a sub-nanoampere readout circuit designed for fast and precise detection with silicon nanowire (SiNW) memristive biosensors via voltage gap measurement. Compared to traditional solutions, the proposed circuit, completed in 65 nm bulk CMOS process, significantly enhances sensitivity to the picoampere range and reduces measurement time from several minutes to one second. Comprehensive performance evaluation has been performed by considering SiNW models with different crossing behavior, including post-layout extraction (PEX) simulations. Accuracy of up to $20-30 \mathrm{mV}$ can be achieved on a particular prescaler configuration, which confirms circuit’s suitability for high-speed biosensing, real-time diagnostics and scalable integration into large sensor arrays.

Thinfilm (Sweden) (SE), Tampere University (FI), École Polytechnique Fédérale de Lausanne (CH), Brno University of Technology (CZ)
Affordable and clean energy
Openalex Percentile: Top 40%
Nanowire Synthesis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.