Parallel high-throughput system for time domain diffuse optical spectroscopy based on a 16-channel SiPM array

The multi-channel SiPM technology is a fascinating leverage for time-resolved diffuse optical spectroscopy thanks to its remarkable parallelization capability that leads to rapidly measuring absorption and scattering properties of a turbid medium at multiple positions across a wide spectral range (600-1000 nm) at high throughput. For clinical applications, where the goal is to characterize the composition of biological tissues (e.g., fat, muscle, bone) in vivo non-invasively, these requirements are critical to support diagnosis with quantitative data, potentially reducing invasive procedures like biopsies and shortening waiting times for clinical exams. Therefore, we developed a time domain diffuse optical spectroscopy (TD-DOS) system based on a compact 16channel Silicon PhotoMultiplier (SiPM) array (footprint of 32 x 45 mm2, with single-photon timing resolution of 65 ps), capable of spectral or spatial parallelization. Spectral parallelization enables swift acquisition of extensive spectra, for example during functional tasks, allowing monitoring of task-related tissue changes and minimizing exam duration without compromising the informative content. Spatial parallelization facilitates tissue mapping or deep-layer investigation by leveraging the relationship between source-detector separation and penetration depth that holds when operating in the time domain. In this work, our system was configured to parallelize wavelengths across the 700-950 nm range (spectral resolution Delta lambda = 16 nm) to match key absorption peaks of hemoglobin and lipids, and the rising edge of water (peaking at 975 nm). Performance was evaluated applying the MEDPHOT protocol on phantoms, showing excellent linearity (worst R-2 = 0. 9973 for absorption and R-2 = 0. 9833 for reduced scattering), minimal absorption-scattering coupling, and remarkable absorption accuracy (average error of 3 % on absolute values), though scattering was overestimated (average error of + 17 %). In vivo trials demonstrated excellent reproducibility (CV < 5 % for absorption and < 4.5 % for scattering over 20 repetitions) and effective characterization of tissue during scans of the back and calf, correlating well with complementary ultrasound information about fat, muscle and bone layering. This system combines for the first time to our knowledge time domain insights, SiPM robustness, and parallelization speed, paving the way for efficient sample characterization in clinical and non-clinical contexts.

Authors

Publication Details

Journal
Optics & Laser Technology
Published
2026-01-14
DOI
https://doi.org/10.1016/j.optlastec.2026.114731
Primary Topic
Optical Polarization and Ellipsometry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Parallel high-throughput system for time domain diffuse optical spectroscopy based on a 16-channel SiPM array

Giulia Maffeis, Alessandro Bossi, Antonio Pifferi, Elisabetta Avanzi et al.
Optics & Laser Technology
Optical Polarization and Ellipsometry
article

Parallel high-throughput system for time domain diffuse optical spectroscopy based on a 16-channel SiPM array

Giulia Maffeis, Alessandro Bossi, Antonio Pifferi, Elisabetta Avanzi, Andrea Farina, Paola Taroni, Valerio Gandolfi, Nicola Serra, Cosimo D’Andrea, Alberto Dalla Mora, Xinqiu Ye Lin, Laura Di Sieno
article en

Abstract

The multi-channel SiPM technology is a fascinating leverage for time-resolved diffuse optical spectroscopy thanks to its remarkable parallelization capability that leads to rapidly measuring absorption and scattering properties of a turbid medium at multiple positions across a wide spectral range (600-1000 nm) at high throughput. For clinical applications, where the goal is to characterize the composition of biological tissues (e.g., fat, muscle, bone) in vivo non-invasively, these requirements are critical to support diagnosis with quantitative data, potentially reducing invasive procedures like biopsies and shortening waiting times for clinical exams. Therefore, we developed a time domain diffuse optical spectroscopy (TD-DOS) system based on a compact 16channel Silicon PhotoMultiplier (SiPM) array (footprint of 32 x 45 mm2, with single-photon timing resolution of 65 ps), capable of spectral or spatial parallelization. Spectral parallelization enables swift acquisition of extensive spectra, for example during functional tasks, allowing monitoring of task-related tissue changes and minimizing exam duration without compromising the informative content. Spatial parallelization facilitates tissue mapping or deep-layer investigation by leveraging the relationship between source-detector separation and penetration depth that holds when operating in the time domain. In this work, our system was configured to parallelize wavelengths across the 700-950 nm range (spectral resolution Delta lambda = 16 nm) to match key absorption peaks of hemoglobin and lipids, and the rising edge of water (peaking at 975 nm). Performance was evaluated applying the MEDPHOT protocol on phantoms, showing excellent linearity (worst R-2 = 0. 9973 for absorption and R-2 = 0. 9833 for reduced scattering), minimal absorption-scattering coupling, and remarkable absorption accuracy (average error of 3 % on absolute values), though scattering was overestimated (average error of + 17 %). In vivo trials demonstrated excellent reproducibility (CV < 5 % for absorption and < 4.5 % for scattering over 20 repetitions) and effective characterization of tissue during scans of the back and calf, correlating well with complementary ultrasound information about fat, muscle and bone layering. This system combines for the first time to our knowledge time domain insights, SiPM robustness, and parallelization speed, paving the way for efficient sample characterization in clinical and non-clinical contexts.

Optics & Laser TechnologyVol. 196
Affordable and clean energy
Openalex Percentile: Top 88%
Optical Polarization and Ellipsometry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.