Estimating effective dose using non-lead protective aprons and a single dosimeter method

Fluoroscopic interventional procedures subject healthcare personnel to significant ionizing radiation exposure, necessitating the use of protective aprons. Protective aprons are made of varying materials and may be subjected to inadequate testing standards, leading to potential inaccuracies estimating effective dose when using single dosimeter methods. This study aims to develop an appropriate method to estimate effective dose for non-lead aprons using a single dosimeter worn outside the apron, thereby enhancing radiation protection and reducing musculoskeletal injuries to workers. A retrospective, secondary analysis of existing literature was conducted to derive a dataset suitable for algorithm development. Transmission of radiation through the protective apron at various thicknesses was modeled using exponential regression. The resulting equation incorporates the nominal lead equivalent thickness to estimate effective dose. Validation was performed by comparing algorithms using two-dosimeters, which do not rely on apron shielding assumptions. The dataset comprised 205 dosimeter readings from 42 physicians across 8243 procedures (Fetterly<i>et al</i>). The derived equation,E=H0(0.13+1.02e(-11.33x)), demonstrated minimal underestimation, and a potential overestimation of up to 1.3-fold relative to the true effective dose, improving upon previous methods by 15%. Inclusion of a non-lead thyroid collar reduced effective dose by 17%-30%. Use of accessory upper body shielding is required when using this method. This novel method provides a method to estimate the effective dose using non-lead aprons at varying nominal lead equivalent thicknesses, surpassing previous single dosimeter approaches. The findings support improved optimization of radiation protection during fluoroscopic interventional procedures, may inform radiation safety regulations, and support ergonomic improvements.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-01-14
DOI
https://doi.org/10.1088/1361-6498/ae3837
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimating effective dose using non-lead protective aprons and a single dosimeter method

JuHyeong Ryu, Jason Daniel Hout
Journal of Radiological Protection
Radiation Dose and Imaging
article

Estimating effective dose using non-lead protective aprons and a single dosimeter method

JuHyeong Ryu, Jason Daniel Hout
article en

Abstract

Fluoroscopic interventional procedures subject healthcare personnel to significant ionizing radiation exposure, necessitating the use of protective aprons. Protective aprons are made of varying materials and may be subjected to inadequate testing standards, leading to potential inaccuracies estimating effective dose when using single dosimeter methods. This study aims to develop an appropriate method to estimate effective dose for non-lead aprons using a single dosimeter worn outside the apron, thereby enhancing radiation protection and reducing musculoskeletal injuries to workers. A retrospective, secondary analysis of existing literature was conducted to derive a dataset suitable for algorithm development. Transmission of radiation through the protective apron at various thicknesses was modeled using exponential regression. The resulting equation incorporates the nominal lead equivalent thickness to estimate effective dose. Validation was performed by comparing algorithms using two-dosimeters, which do not rely on apron shielding assumptions. The dataset comprised 205 dosimeter readings from 42 physicians across 8243 procedures (Fetterly<i>et al</i>). The derived equation,E=H0(0.13+1.02e(-11.33x)), demonstrated minimal underestimation, and a potential overestimation of up to 1.3-fold relative to the true effective dose, improving upon previous methods by 15%. Inclusion of a non-lead thyroid collar reduced effective dose by 17%-30%. Use of accessory upper body shielding is required when using this method. This novel method provides a method to estimate the effective dose using non-lead aprons at varying nominal lead equivalent thicknesses, surpassing previous single dosimeter approaches. The findings support improved optimization of radiation protection during fluoroscopic interventional procedures, may inform radiation safety regulations, and support ergonomic improvements.

Journal of Radiological ProtectionVol. 46(1)
West Virginia University (US), Mayo Clinic (US), Mayo Clinic in Florida (US)
Good health and well-being
Openalex Percentile: Top 89%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.