Dataset on the performance of a photovoltaic solar water pump in coffee plantations using response surface methodology (RSM)

This dataset presents experimental data on the performance of a photovoltaic (PV) solar-powered water pumping system installed in a coffee plantation in Chiang Mai province, Thailand. The system performance was evaluated through controlled experiments using response surface methodology (RSM). Three independent variables were systematically varied: solar irradiance (300-900 W/m²), panel inclination (15-35°), and panel surface temperature (30-60°C). A total of 15 experimental runs were conducted, and the pumping efficiency (%) was recorded under each condition. Statistical analyses, including analysis of variance (ANOVA) and regression modeling, were applied to evaluate the effects of the individual variables and their interactions on system performance. The dataset includes raw and processed measurements, regression coefficients, and response surface parameters, enabling replication and further analysis. Perturbation plots, 3D surface plots, and contour plots provide detailed visualizations of the relationships between environmental factors and system efficiency. The optimal operating conditions were identified at a solar irradiance of 600 W/m², a panel inclination of 25°, and a panel surface temperature of 45°C, corresponding to a predicted maximum efficiency of 76.3-77.0%. This dataset can be reused for designing optimized solar water pumping systems, validating predictive models, and comparing system performance under different environmental conditions or geographic locations. It also serves as a reference for researchers in renewable energy system optimization and agricultural water management. The data provide high-resolution, experimentally validated information on the combined effects of solar irradiance, panel inclination, and panel surface temperature on PV water pumping efficiency. Unlike previous studies, it includes detailed quantitative analysis specific to coffee-growing regions in Northern Thailand, along with regression models and visualizations that can guide both experimental replication and predictive modeling under similar climatic and agricultural conditions.

Authors

Institutions

Publication Details

Journal
Data in Brief
Published
2026-01-14
DOI
https://doi.org/10.1016/j.dib.2026.112467
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dataset on the performance of a photovoltaic solar water pump in coffee plantations using response surface methodology (RSM)

Nopparat Suriyachai, Saksit Imman, Torpong Kreetachat
Data in Brief
Photovoltaic System Optimization Techniques
article

Dataset on the performance of a photovoltaic solar water pump in coffee plantations using response surface methodology (RSM)

Nopparat Suriyachai, Saksit Imman, Torpong Kreetachat
article en

Abstract

This dataset presents experimental data on the performance of a photovoltaic (PV) solar-powered water pumping system installed in a coffee plantation in Chiang Mai province, Thailand. The system performance was evaluated through controlled experiments using response surface methodology (RSM). Three independent variables were systematically varied: solar irradiance (300-900 W/m²), panel inclination (15-35°), and panel surface temperature (30-60°C). A total of 15 experimental runs were conducted, and the pumping efficiency (%) was recorded under each condition. Statistical analyses, including analysis of variance (ANOVA) and regression modeling, were applied to evaluate the effects of the individual variables and their interactions on system performance. The dataset includes raw and processed measurements, regression coefficients, and response surface parameters, enabling replication and further analysis. Perturbation plots, 3D surface plots, and contour plots provide detailed visualizations of the relationships between environmental factors and system efficiency. The optimal operating conditions were identified at a solar irradiance of 600 W/m², a panel inclination of 25°, and a panel surface temperature of 45°C, corresponding to a predicted maximum efficiency of 76.3-77.0%. This dataset can be reused for designing optimized solar water pumping systems, validating predictive models, and comparing system performance under different environmental conditions or geographic locations. It also serves as a reference for researchers in renewable energy system optimization and agricultural water management. The data provide high-resolution, experimentally validated information on the combined effects of solar irradiance, panel inclination, and panel surface temperature on PV water pumping efficiency. Unlike previous studies, it includes detailed quantitative analysis specific to coffee-growing regions in Northern Thailand, along with regression models and visualizations that can guide both experimental replication and predictive modeling under similar climatic and agricultural conditions.

Data in BriefVol. 65
University of Phayao (TH)
Openalex Percentile: Top 89%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.