Robust configuration optimisation of low-carbon integrated energy systems under variable equipment efficiency and source-load uncertainty conditions

Integrated energy systems (IES) are critical for decarbonising urban energy, yet their design faces challenges arising from renewable intermittency, stochastic occupant demand, and equipment performance under off-design conditions, an area often overlooked in existing optimisation models. This study proposes a two stage robust optimisation framework for IES that jointly addresses renewable supply variability, stochastic demand and off design equipment performance to address this gap. This approach links micro-level occupant behaviour and equipment physics with system-level capacity planning, yielding configurations that hedge uncertainty while maintaining operational adaptability. Introducing photovoltaic (PV) uncertainty increases optimal PV capacity by 16.4%. Accounting for off-design operation shifts the configuration towards dispatchable units, gas turbine, waste heat boiler, and absorption chiller, whose capacities increase by 21.0%, 17.5%, and 17.2%, respectively, with a 3.46% increase in total annualised cost. Sensitivity to the uncertainty budget Γ shows that reducing Γ from 14 to 0 lowers annualised cost by 2.24% and investment by 5.94%, with diminishing returns beyond Γ > 9. Seasonal dispatch confirms adaptive roles: electric chillers dominate summer cooling, gas boilers dominate winter heating, and waste heat boilers dominate transitional heating. The framework supports uncertainty-aware planning and policy design; however, it has some limitations, including the absence of explicit carbon cost/constraints. Future work will extend to multi-objective (cost–carbon–resilience), dynamic pricing/demand response, and broader behavioural modelling across building types and climates. • Developed a two-stage robust optimisation framework for Integrated Energy Systems (IES) that jointly addresses PV supply uncertainty, stochastic demand, and off-design equipment performance. • Generated community-scale stochastic load profiles using k-means clustering and Monte Carlo simulation, validated with MAPE < 5%. • Incorporating off-design characteristics increased annualised cost by 3.46% , while reducing PV uncertainty (Γ) from 14 to 0 lowered cost by 2.24% and investment by 5.94%. • Seasonal dispatch analysis confirmed adaptability: electric chillers dominate summer cooling, gas boilers dominate winter heating, and waste heat boilers dominate heating during transitional periods, with other units contributing as complementary sources. • Findings inform balanced robustness targets and policy frameworks for flexible, multi-energy systems in sustainable urban planning.

Authors

Institutions

Publication Details

Journal
Energy
Published
2026-01-14
DOI
https://doi.org/10.1016/j.energy.2026.140046
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust configuration optimisation of low-carbon integrated energy systems under variable equipment efficiency and source-load uncertainty conditions

Yuhang Ma, H. Zhong, Jianan Qian, Wangxi Gu et al.
Energy
Integrated Energy Systems Optimization
article

Robust configuration optimisation of low-carbon integrated energy systems under variable equipment efficiency and source-load uncertainty conditions

Yuhang Ma, H. Zhong, Jianan Qian, Wangxi Gu, Shuqin Chen
article en

Abstract

Integrated energy systems (IES) are critical for decarbonising urban energy, yet their design faces challenges arising from renewable intermittency, stochastic occupant demand, and equipment performance under off-design conditions, an area often overlooked in existing optimisation models. This study proposes a two stage robust optimisation framework for IES that jointly addresses renewable supply variability, stochastic demand and off design equipment performance to address this gap. This approach links micro-level occupant behaviour and equipment physics with system-level capacity planning, yielding configurations that hedge uncertainty while maintaining operational adaptability. Introducing photovoltaic (PV) uncertainty increases optimal PV capacity by 16.4%. Accounting for off-design operation shifts the configuration towards dispatchable units, gas turbine, waste heat boiler, and absorption chiller, whose capacities increase by 21.0%, 17.5%, and 17.2%, respectively, with a 3.46% increase in total annualised cost. Sensitivity to the uncertainty budget Γ shows that reducing Γ from 14 to 0 lowers annualised cost by 2.24% and investment by 5.94%, with diminishing returns beyond Γ > 9. Seasonal dispatch confirms adaptive roles: electric chillers dominate summer cooling, gas boilers dominate winter heating, and waste heat boilers dominate transitional heating. The framework supports uncertainty-aware planning and policy design; however, it has some limitations, including the absence of explicit carbon cost/constraints. Future work will extend to multi-objective (cost–carbon–resilience), dynamic pricing/demand response, and broader behavioural modelling across building types and climates. • Developed a two-stage robust optimisation framework for Integrated Energy Systems (IES) that jointly addresses PV supply uncertainty, stochastic demand, and off-design equipment performance. • Generated community-scale stochastic load profiles using k-means clustering and Monte Carlo simulation, validated with MAPE < 5%. • Incorporating off-design characteristics increased annualised cost by 3.46% , while reducing PV uncertainty (Γ) from 14 to 0 lowered cost by 2.24% and investment by 5.94%. • Seasonal dispatch analysis confirmed adaptability: electric chillers dominate summer cooling, gas boilers dominate winter heating, and waste heat boilers dominate heating during transitional periods, with other units contributing as complementary sources. • Findings inform balanced robustness targets and policy frameworks for flexible, multi-energy systems in sustainable urban planning.

EnergyVol. 345
London South Bank University (GB), Zhejiang University (CN)
Openalex Percentile: Top 88%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.