Introduction Various couplers exist for the Vibrant Soundbridge implant to connect the actuator to a middle ear structure. While the surgical indication mainly distinguishes between purely sensorineural hearing loss and mixed hearing loss, and audiological indication ranges are designed accordingly, we believe that the biomechanical distinction between forward and reverse cochlear stimulation is more meaningful. To evaluate this, we apply all common couplers in temporal bone experiments and correct the measurements for adequate comparability.Material And Methods The study was conducted at two research labs, each with n = 10 cadaveric temporal bones. Laser Doppler velocity measurements on the stapes were used for direct comparison between the coupling methods. Therefore, reverse cochlear stimulation requires a correction factor due to pressure loss through a third window. This was calculated by measuring intracochlear pressure differences in the same specimens.Results Compared to the stapes LDV measurement, reverse stimulations require a correction factor that continuously decreases in the high frequency range: approximately +22.4 dB between 125-250 Hz, +7.9 dB between 300-800 Hz, and +4.8 dB above 1000 Hz. Taking this into account, there is still a considerable difference between the forward and reverse stimulation methods of 15-22 dB in the frequency range <2000 Hz and approximately 7 dB >2000 Hz to the favor of forward stimulation.Conclusions Forward couplings, including direct stapes coupling, are mechanically superior to reverse stimulation. The stapes head coupler performs 7-25 dB better than the round window coupler and similar or even superior to incus couplers.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-01-06
DOI
https://doi.org/10.48620/93793
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental comparison between forward and reverse Vibrant Soundbridge cochlear stimulation.

Christof Stieger, Mohammad Ghoncheh, Hamidreza Mojallal, David Stauske et al.
Open Access CRIS of the University of Bern
Ear Surgery and Otitis Media
article

Experimental comparison between forward and reverse Vibrant Soundbridge cochlear stimulation.

Christof Stieger, Mohammad Ghoncheh, Hamidreza Mojallal, David Stauske, Hannes Maier, Lukas Graf, Andreas Arnold
article en

Abstract

Introduction Various couplers exist for the Vibrant Soundbridge implant to connect the actuator to a middle ear structure. While the surgical indication mainly distinguishes between purely sensorineural hearing loss and mixed hearing loss, and audiological indication ranges are designed accordingly, we believe that the biomechanical distinction between forward and reverse cochlear stimulation is more meaningful. To evaluate this, we apply all common couplers in temporal bone experiments and correct the measurements for adequate comparability.Material And Methods The study was conducted at two research labs, each with n = 10 cadaveric temporal bones. Laser Doppler velocity measurements on the stapes were used for direct comparison between the coupling methods. Therefore, reverse cochlear stimulation requires a correction factor due to pressure loss through a third window. This was calculated by measuring intracochlear pressure differences in the same specimens.Results Compared to the stapes LDV measurement, reverse stimulations require a correction factor that continuously decreases in the high frequency range: approximately +22.4 dB between 125-250 Hz, +7.9 dB between 300-800 Hz, and +4.8 dB above 1000 Hz. Taking this into account, there is still a considerable difference between the forward and reverse stimulation methods of 15-22 dB in the frequency range <2000 Hz and approximately 7 dB >2000 Hz to the favor of forward stimulation.Conclusions Forward couplings, including direct stapes coupling, are mechanically superior to reverse stimulation. The stapes head coupler performs 7-25 dB better than the round window coupler and similar or even superior to incus couplers.

Open Access CRIS of the University of Bern
Carolina Ear, Nose and Throat Clinic (US)
Openalex Percentile: Top 89%
Ear Surgery and Otitis Media
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental comparison between forward and reverse Vibrant Soundbridge cochlear stimulation. — Christof Stieger, Mohammad Ghoncheh, et al. · Open Access CRIS of the University of Bern (2026) | TGRS Research Map | TGRS