Cherenkov emission–based quality assurance for linear accelerators

When electrons exceed the speed of light in a medium, they emit low-intensity visible light, known as Cherenkov emission (CE). This study proposes a novel CE-based quality assurance (QA) test for linear accelerators. A CE-based QA (C-QA) phantom incorporating a mock tumor and four CE observation plates (top, bottom, left, and right) was developed. After tumor-based alignment using cone-beam computed tomography (CBCT), lateral and posterior fields were used for irradiation. A C-Dose camera was employed to measure the treatment position, gantry angle, photon energy (TPR20,10), and CE counts for both fields. The treatment position and TPR20,10 were determined by analyzing the changes in the CE profile, while the gantry angle was calculated based on the tilt between the entry and exit field positions. Confidence limits were evaluated over a three-month period, during which long-term testing demonstrated favorable results. The standard deviations (σ) for CBCT-based positional accuracy and gantry angle were within ±1 mm in all three directions and within 1°, respectively. The mean ± σ for TPR20,10 was 0.631 ± 0.004, closely matching the 0.629 measured using an ionization chamber. Detected CE counts exhibited a higher variation (σ = 2.7%). CE-based QA appears to be an effective and reliable method for radiotherapy. Treatment position could be directly measured without conventional dosimetric devices, while CE imaging simultaneously evaluated positional accuracy, gantry angle, and photon energy (TPR20,10). However, accurate assessment of linear accelerator dose output remains a challenge, and the quantification of CE counts requires further investigation.

Authors

Institutions

Publication Details

Journal
Journal of Radiation Research
Published
2025-10-21
DOI
https://doi.org/10.1093/jrr/rraf072
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cherenkov emission–based quality assurance for linear accelerators

Y. Nakajima, Takahito Chiba, K. Iijima, Yuka Kondou et al.
Journal of Radiation Research
Advanced Radiotherapy Techniques
article

Cherenkov emission–based quality assurance for linear accelerators

Y. Nakajima, Takahito Chiba, K. Iijima, Yuka Kondou, Tetsu Nakaichi, Masataka Ueda, Miyuki Murata, Yukio Fujita, Kazuyoshi Kurita, Hiroyuki Okamoto, Aya Shimoike, Hiroki Nakayama, Hiroshi Igaki, Satoshi Nakamura, Fuma Tojo
article en

Abstract

When electrons exceed the speed of light in a medium, they emit low-intensity visible light, known as Cherenkov emission (CE). This study proposes a novel CE-based quality assurance (QA) test for linear accelerators. A CE-based QA (C-QA) phantom incorporating a mock tumor and four CE observation plates (top, bottom, left, and right) was developed. After tumor-based alignment using cone-beam computed tomography (CBCT), lateral and posterior fields were used for irradiation. A C-Dose camera was employed to measure the treatment position, gantry angle, photon energy (TPR20,10), and CE counts for both fields. The treatment position and TPR20,10 were determined by analyzing the changes in the CE profile, while the gantry angle was calculated based on the tilt between the entry and exit field positions. Confidence limits were evaluated over a three-month period, during which long-term testing demonstrated favorable results. The standard deviations (σ) for CBCT-based positional accuracy and gantry angle were within ±1 mm in all three directions and within 1°, respectively. The mean ± σ for TPR20,10 was 0.631 ± 0.004, closely matching the 0.629 measured using an ionization chamber. Detected CE counts exhibited a higher variation (σ = 2.7%). CE-based QA appears to be an effective and reliable method for radiotherapy. Treatment position could be directly measured without conventional dosimetric devices, while CE imaging simultaneously evaluated positional accuracy, gantry angle, and photon energy (TPR20,10). However, accurate assessment of linear accelerator dose output remains a challenge, and the quantification of CE counts requires further investigation.

Journal of Radiation ResearchVol. 67(1)
Rikkyo University (JP), Juntendo University (JP), National Cancer Center (US), National Cancer Research Institute (GB), Komazawa University (JP)
Affordable and clean energy
Openalex Percentile: Top 25%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.