High-Fidelity rPPG Waveform Reconstruction from Palm Videos Using GANs

Remote photoplethysmography (rPPG) enables non-contact acquisition of human physiological parameters using ordinary cameras, and has been widely applied in medical monitoring, human-computer interaction, and health management. However, most existing studies focus on estimating specific physiological metrics, such as heart rate and heart rate variability, while paying insufficient attention to reconstructing the underlying rPPG waveform. In addition, publicly available datasets typically record facial videos accompanied by fingertip PPG signals as reference labels. Since fingertip PPG waveforms differ substantially from the true photoplethysmography (PPG) signals obtained from the face, deep learning models trained on such datasets often struggle to recover high-quality rPPG waveforms. To address this issue, we collected a new dataset consisting of palm-region videos paired with wrist-based PPG signals as reference labels, and experimentally validated its effectiveness for training neural network models aimed at rPPG waveform reconstruction. Furthermore, we propose a generative adversarial network (GAN)-based pulse-wave synthesis framework that produces high-quality rPPG waveforms by denoising the mean green-channel signal. By incorporating time-domain peak-aware loss, frequency-domain loss, and adversarial loss, our method achieves promising performance, with an RMSE (Root Mean Square Error) of 0.102, an MAPE (Mean Absolute Percentage Error) of 0.028, a Pearson correlation of 0.987, and a cosine similarity of 0.989. These results demonstrate the capability of the proposed approach to reconstruct high-fidelity rPPG waveforms with improved morphological accuracy compared to noisy raw rPPG signals, rather than directly validating health monitoring performance. This study presents a high-quality rPPG waveform reconstruction approach from both data and model perspectives, providing a reliable foundation for subsequent physiological signal analysis, waveform-based studies, and potential health-related applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-14
DOI
https://doi.org/10.3390/s26020563
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Fidelity rPPG Waveform Reconstruction from Palm Videos Using GANs

Tao Li, Yuliang Liu
Sensors
Non-Invasive Vital Sign Monitoring
article

High-Fidelity rPPG Waveform Reconstruction from Palm Videos Using GANs

Tao Li, Yuliang Liu
article en

Abstract

Remote photoplethysmography (rPPG) enables non-contact acquisition of human physiological parameters using ordinary cameras, and has been widely applied in medical monitoring, human-computer interaction, and health management. However, most existing studies focus on estimating specific physiological metrics, such as heart rate and heart rate variability, while paying insufficient attention to reconstructing the underlying rPPG waveform. In addition, publicly available datasets typically record facial videos accompanied by fingertip PPG signals as reference labels. Since fingertip PPG waveforms differ substantially from the true photoplethysmography (PPG) signals obtained from the face, deep learning models trained on such datasets often struggle to recover high-quality rPPG waveforms. To address this issue, we collected a new dataset consisting of palm-region videos paired with wrist-based PPG signals as reference labels, and experimentally validated its effectiveness for training neural network models aimed at rPPG waveform reconstruction. Furthermore, we propose a generative adversarial network (GAN)-based pulse-wave synthesis framework that produces high-quality rPPG waveforms by denoising the mean green-channel signal. By incorporating time-domain peak-aware loss, frequency-domain loss, and adversarial loss, our method achieves promising performance, with an RMSE (Root Mean Square Error) of 0.102, an MAPE (Mean Absolute Percentage Error) of 0.028, a Pearson correlation of 0.987, and a cosine similarity of 0.989. These results demonstrate the capability of the proposed approach to reconstruct high-fidelity rPPG waveforms with improved morphological accuracy compared to noisy raw rPPG signals, rather than directly validating health monitoring performance. This study presents a high-quality rPPG waveform reconstruction approach from both data and model perspectives, providing a reliable foundation for subsequent physiological signal analysis, waveform-based studies, and potential health-related applications.

SensorsVol. 26(2)
Chinese Academy of Sciences (CN), Institute of Semiconductors (CN), University of Chinese Academy of Sciences (CN)
Chinese Academy of Sciences, University of Chinese Academy of Sciences
Openalex Percentile: Top 89%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.