A clinical shift toward personalized cochlear implantation: Using preoperative planning to optimize insertion depth.

Objective To evaluate the clinical implementation of preoperative, anatomy-tailored planning for electrode selection in cochlear implantation, quantify planning accuracy under routine conditions, and identify factors associated with deviations from the planned angular insertion depth (AID).Methods We retrospectively analyzed 71 consecutive implantations; 17 cases were excluded due to unsuccessful segmentation/fusion, yielding 54 implanted ears. Before 2023 (Group A, n=32), electrode choice followed surgeon preference independent of cochlear duct length (CDL). From 2023 (Group B, n=22), automated OTOPLAN-based planning targeted an AID of 600° (cap 650°). Pre- and postoperative computed tomography scans provided cochlear metrics and postoperative AID. Planning accuracy was defined as the difference between planned and achieved AID. Linear models assessed demographic/clinical, anatomical, and surgical predictors. Speech outcomes at 6 months used Freiburger monosyllables at 65 dB HL.Results Group B showed deeper and more consistent insertions (median AID 568° [IQR 62°]) than Group A (527° [IQR 99°]; p<0.01). Median planning deviation was -9∘ (IQR 78°) with no relationship to planned depth ( R2=0.008, p=0.514). Greater inaccuracies were found in patients with shorter CDL (p=0.001) and in cases with observed intraoperative resistance (p<0.001).Conclusion cochlear anatomy exhibited substantial inter-individual variability. Implementing preoperative, anatomy-tailored planning was associated with the selection of longer arrays, deeper and more consistent AID, and overall high planning accuracy. Deviations from the planned position were primarily linked to shorter CDL and intraoperative resistance, whereas deeper targets themselves did not reduce accuracy. Audiological performance at 6 months did not differ significantly between groups, although a modest trend favored the planned cohort. These findings support the feasibility of routine, examiner-independent planning and suggest that patient-specific anatomical markers should inform the selection of an appropriate electrode array.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-12-11
DOI
https://doi.org/10.48620/93789
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A clinical shift toward personalized cochlear implantation: Using preoperative planning to optimize insertion depth.

Marco Caversaccio, Wilhelm Wimmer, Philipp Aebischer, Stephan Schraivogel et al.
Open Access CRIS of the University of Bern
Hearing Loss and Rehabilitation
article

A clinical shift toward personalized cochlear implantation: Using preoperative planning to optimize insertion depth.

Marco Caversaccio, Wilhelm Wimmer, Philipp Aebischer, Stephan Schraivogel, Stefan Weder, Georgios Mantokoudis, Benjamin Bircher
article en

Abstract

Objective To evaluate the clinical implementation of preoperative, anatomy-tailored planning for electrode selection in cochlear implantation, quantify planning accuracy under routine conditions, and identify factors associated with deviations from the planned angular insertion depth (AID).Methods We retrospectively analyzed 71 consecutive implantations; 17 cases were excluded due to unsuccessful segmentation/fusion, yielding 54 implanted ears. Before 2023 (Group A, n=32), electrode choice followed surgeon preference independent of cochlear duct length (CDL). From 2023 (Group B, n=22), automated OTOPLAN-based planning targeted an AID of 600° (cap 650°). Pre- and postoperative computed tomography scans provided cochlear metrics and postoperative AID. Planning accuracy was defined as the difference between planned and achieved AID. Linear models assessed demographic/clinical, anatomical, and surgical predictors. Speech outcomes at 6 months used Freiburger monosyllables at 65 dB HL.Results Group B showed deeper and more consistent insertions (median AID 568° [IQR 62°]) than Group A (527° [IQR 99°]; p<0.01). Median planning deviation was -9∘ (IQR 78°) with no relationship to planned depth ( R2=0.008, p=0.514). Greater inaccuracies were found in patients with shorter CDL (p=0.001) and in cases with observed intraoperative resistance (p<0.001).Conclusion cochlear anatomy exhibited substantial inter-individual variability. Implementing preoperative, anatomy-tailored planning was associated with the selection of longer arrays, deeper and more consistent AID, and overall high planning accuracy. Deviations from the planned position were primarily linked to shorter CDL and intraoperative resistance, whereas deeper targets themselves did not reduce accuracy. Audiological performance at 6 months did not differ significantly between groups, although a modest trend favored the planned cohort. These findings support the feasibility of routine, examiner-independent planning and suggest that patient-specific anatomical markers should inform the selection of an appropriate electrode array.

Open Access CRIS of the University of Bern
Carolina Ear, Nose and Throat Clinic (US)
Openalex Percentile: Top 29%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.