Using Generators with Operating Voltage of 50 kV for Electric Discharge Crushing of Quartz Raw

The results of using two generators with an operating voltage of about 50 kV for high voltage electric pulse crushing of quartz raw are presented. A comparison with previously obtained results of quartz raw crushing on a generator with an operating voltage of 250 kV is performed. Reducing the operating voltage of the generator allows improving its operating qualities and simplifying the generator design due to the exclusion of a step-up pulse transformer from the circuit. It is shown that while maintaining the energy level in the high-voltage storage and reducing the operating voltage from 250 to 50 kV, the crushing efficiency remains at the same level. An increase in the stored energy while other parameters constant does not lead to an increase in the crushing efficiency, since energy consumption and the proportion of overgrinding fraction increase.

Authors

Institutions

Publication Details

Journal
Bulletin of the Russian Academy of Sciences Physics
Published
2025-12-01
DOI
https://doi.org/10.1134/s1062873825714333
Primary Topic
Mineral Processing and Grinding
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using Generators with Operating Voltage of 50 kV for Electric Discharge Crushing of Quartz Raw

A. P. Zhaboedov, A. A. Zherlitsyn, A. I. Nepomnyashchikh, V. M. Alexeenko et al.
Bulletin of the Russian Academy of Sciences Physics
Mineral Processing and Grinding
article

Using Generators with Operating Voltage of 50 kV for Electric Discharge Crushing of Quartz Raw

A. P. Zhaboedov, A. A. Zherlitsyn, A. I. Nepomnyashchikh, V. M. Alexeenko, A. G. Sitnikov, S. S. Kondratiev
article en

Abstract

The results of using two generators with an operating voltage of about 50 kV for high voltage electric pulse crushing of quartz raw are presented. A comparison with previously obtained results of quartz raw crushing on a generator with an operating voltage of 250 kV is performed. Reducing the operating voltage of the generator allows improving its operating qualities and simplifying the generator design due to the exclusion of a step-up pulse transformer from the circuit. It is shown that while maintaining the energy level in the high-voltage storage and reducing the operating voltage from 250 to 50 kV, the crushing efficiency remains at the same level. An increase in the stored energy while other parameters constant does not lead to an increase in the crushing efficiency, since energy consumption and the proportion of overgrinding fraction increase.

Bulletin of the Russian Academy of Sciences PhysicsVol. 89(S2)
Vinogradov Institute of Geochemistry (RU), Institute of High Current Electronics (RU)
Affordable and clean energy
Openalex Percentile: Top 42%
Mineral Processing and Grinding
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Using Generators with Operating Voltage of 50 kV for Electric Discharge Crushing of Quartz Raw — A. P. Zhaboedov, A. A. Zherlitsyn, et al. · Bulletin of the Russian Academy of Sciences Physics (2025) | TGRS Research Map | TGRS