Silane‐Grafted Schiff Base for Selective Ni(II) Detection: Optical Sensing, Cytotoxicity on HeLa Cells, and Its Real Sample Evaluation

ABSTRACT A novel silane–grafted Schiff base derivative, designated as compound 3 , was synthesized and thoroughly characterized using 1 H NMR, 13 C NMR, FT‐IR, and mass spectrometry. The formation of its Ni(II) complex was confirmed by FT‐IR, mass spectrometry, and DFT calculations. Photophysical studies revealed that compound 3 exhibits excellent selectivity and sensitivity toward Ni(II) ions, with low detection limits of 2.6 × 10 −8 M (UV–Vis) and 3.0 × 10 −10 M (fluorescence). DFT analysis supported the experimental findings, indicating the formation of a stable and energetically favorable complex. The compound also showed high accuracy in detecting Ni(II) in real water samples and exhibited low cytotoxicity toward HeLa cells, suggesting potential applications in both environmental monitoring and biological sensing. Overall, compound 3 functions as a stable, sensitive, and multifunctional fluorescent probe for Ni(II) ion detection.

Authors

Institutions

Publication Details

Journal
Applied Organometallic Chemistry
Published
2026-01-14
DOI
https://doi.org/10.1002/aoc.70506
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Silane‐Grafted Schiff Base for Selective Ni(II) Detection: Optical Sensing, Cytotoxicity on HeLa Cells, and Its Real Sample Evaluation

Shreya Thakur, T Dhir, Tsering Diskit, Gurjaspreet Singh et al.
Applied Organometallic Chemistry
Molecular Sensors and Ion Detection
article

Silane‐Grafted Schiff Base for Selective Ni(II) Detection: Optical Sensing, Cytotoxicity on HeLa Cells, and Its Real Sample Evaluation

Shreya Thakur, T Dhir, Tsering Diskit, Gurjaspreet Singh, K. N. Singh, Baljinder Singh Gill, Shivani Thakur, Deepanjali Baliyan, Puspa, Monika
article en

Abstract

ABSTRACT A novel silane–grafted Schiff base derivative, designated as compound 3 , was synthesized and thoroughly characterized using 1 H NMR, 13 C NMR, FT‐IR, and mass spectrometry. The formation of its Ni(II) complex was confirmed by FT‐IR, mass spectrometry, and DFT calculations. Photophysical studies revealed that compound 3 exhibits excellent selectivity and sensitivity toward Ni(II) ions, with low detection limits of 2.6 × 10 −8 M (UV–Vis) and 3.0 × 10 −10 M (fluorescence). DFT analysis supported the experimental findings, indicating the formation of a stable and energetically favorable complex. The compound also showed high accuracy in detecting Ni(II) in real water samples and exhibited low cytotoxicity toward HeLa cells, suggesting potential applications in both environmental monitoring and biological sensing. Overall, compound 3 functions as a stable, sensitive, and multifunctional fluorescent probe for Ni(II) ion detection.

Applied Organometallic ChemistryVol. 40(2)
Central University of Punjab (IN), Panjab University (IN)
Clean water and sanitation
Openalex Percentile: Top 89%
Molecular Sensors and Ion Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.