Centrifuge tests on the load-bearing behaviour of prefabricated concrete screw-type piles

Due to very low noise emission during installation, prefabricated concrete screw-type piles (PCSP) could potentially be viable options as foundations for offshore and onshore structures. However, little attention has been paid to the axial load-bearing behaviour in compression of this specific prefabricated screw-type pile system in comparison with conventional displacement pile systems. This article describes an experimental campaign of centrifuge tests performed at 100g on both screw-type piles and straight shafted piles (SP) with diameters of 550 and 475 mm at prototype scale. The outer screw diameter (Ds) to pile core diameter (D) ratio amounted to Ds/D = 1.25, and the screw pitch (Lp) to pile core diameter (D) ratio (pitch ratio) was selected as Lp/D = 0.57. Saturated Vingerling Clay was used to model the soil layer, and a low loading rate was selected to simulate drained conditions. Piles were installed at 1g; therefore, the pile installation process was not fully modelled. For both pile diameters investigated, the results indicate an approximately 45% higher bearing capacity with the PCSP compared with the capacity of the SP.

Authors

Institutions

Publication Details

Journal
International Journal of Physical Modelling in Geotechnics
Published
2026-01-13
DOI
https://doi.org/10.1680/jphmg.25.00036
Primary Topic
Geotechnical Engineering and Soil Mechanics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Centrifuge tests on the load-bearing behaviour of prefabricated concrete screw-type piles

Q. Li, André Arnold, Gregor Portmann
International Journal of Physical Modelling in Geotechnics
Geotechnical Engineering and Soil Mechanics
article

Centrifuge tests on the load-bearing behaviour of prefabricated concrete screw-type piles

Q. Li, André Arnold, Gregor Portmann
article en

Abstract

Due to very low noise emission during installation, prefabricated concrete screw-type piles (PCSP) could potentially be viable options as foundations for offshore and onshore structures. However, little attention has been paid to the axial load-bearing behaviour in compression of this specific prefabricated screw-type pile system in comparison with conventional displacement pile systems. This article describes an experimental campaign of centrifuge tests performed at 100g on both screw-type piles and straight shafted piles (SP) with diameters of 550 and 475 mm at prototype scale. The outer screw diameter (Ds) to pile core diameter (D) ratio amounted to Ds/D = 1.25, and the screw pitch (Lp) to pile core diameter (D) ratio (pitch ratio) was selected as Lp/D = 0.57. Saturated Vingerling Clay was used to model the soil layer, and a low loading rate was selected to simulate drained conditions. Piles were installed at 1g; therefore, the pile installation process was not fully modelled. For both pile diameters investigated, the results indicate an approximately 45% higher bearing capacity with the PCSP compared with the capacity of the SP.

International Journal of Physical Modelling in GeotechnicsVol. 26(2)
Lucerne University of Applied Sciences and Arts (CH), Delft University of Technology (NL)
Technische Universiteit Delft, Innosuisse - Schweizerische Agentur für Innovationsförderung
Life below water
Openalex Percentile: Top 89%
Geotechnical Engineering and Soil Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.