Simulation of radiation situation inside a cyclotron vault during production of 18F

Abstract The safe operation of medical cyclotrons used for producing PET radiopharmaceuticals like fluorine-18 necessitates a thorough understanding of the surrounding radiation fields. This study presents a comprehensive analysis of the neutron and gamma radiation environment around an IBA Cyclone 18/9. Using the MCNP6.2 code, a detailed model of the cyclotron vault was developed, incorporating radiation sources from both the 18O(p,xn) reaction in the water target and proton beam losses on accelerator components. The simulated dose equivalents were validated against experimental measurements from neutron and gamma probes located outside the vault. Results indicate that while primary gamma rays are effectively shielded, neutrons are the dominant contributor to the dose outside the vault. Furthermore, the gamma dose measured externally is primarily a result of secondary gamma rays produced from neutron interactions with the shielding and structural materials. The agreement between simulation and measurement demonstrates the reliability of the model for evaluating radiation exposure and designing effective shielding around medical cyclotrons.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Engineering and Radiation Science
Published
2026-01-13
DOI
https://doi.org/10.1115/1.4070864
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of radiation situation inside a cyclotron vault during production of 18F

Šimon Vadják, Marek Zmeškal
Journal of Nuclear Engineering and Radiation Science
Radiopharmaceutical Chemistry and Applications
article

Simulation of radiation situation inside a cyclotron vault during production of 18F

Šimon Vadják, Marek Zmeškal
article en

Abstract

Abstract The safe operation of medical cyclotrons used for producing PET radiopharmaceuticals like fluorine-18 necessitates a thorough understanding of the surrounding radiation fields. This study presents a comprehensive analysis of the neutron and gamma radiation environment around an IBA Cyclone 18/9. Using the MCNP6.2 code, a detailed model of the cyclotron vault was developed, incorporating radiation sources from both the 18O(p,xn) reaction in the water target and proton beam losses on accelerator components. The simulated dose equivalents were validated against experimental measurements from neutron and gamma probes located outside the vault. Results indicate that while primary gamma rays are effectively shielded, neutrons are the dominant contributor to the dose outside the vault. Furthermore, the gamma dose measured externally is primarily a result of secondary gamma rays produced from neutron interactions with the shielding and structural materials. The agreement between simulation and measurement demonstrates the reliability of the model for evaluating radiation exposure and designing effective shielding around medical cyclotrons.

Journal of Nuclear Engineering and Radiation Science
Research Centre Rez (CZ), Nuclear Research Institute Rez (Czechia) (CZ)
Clean water and sanitation
Openalex Percentile: Top 90%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation of radiation situation inside a cyclotron vault during production of 18F — Šimon Vadják, Marek Zmeškal · Journal of Nuclear Engineering and Radiation Science (2026) | TGRS Research Map | TGRS