Palmaris Longus Muscle and Its Variations: Ultrasound, Anatomical and Histological Study with Clinical and Surgical Applications

Background/objective: The palmaris longus muscle is a variable and often inconsistent muscle in the anterior compartment of the forearm. This fusiform-shaped muscle originates at the medial epicondyle of the humerus bone following a long and narrow tendon that inserts at the palmar aponeurosis. That tendon is used in reconstructive surgery, and for this reason, detailed information from an ultrasound is used to detect the tendon and the possible variations in the muscle. The present study aimed to investigate the palmaris longus muscle and its variations through ultrasound, anatomical, and histological analysis with clinical and surgical applications. Methods: A total of 72 upper limbs from 33 females and 39 males, 32 right and 40 left, were evaluated in ultrasound, anatomical, and histological studies. The main objective was to prove the existence of the palmaris longus muscle and its variations, as well as to measure the tendon for surgical applications. Results: Ultrasound analysis showed that it is possible to determine the existence of the muscle (76.4%) and its variations (23.6%), as well as its absence (15.3%). The anatomical results proved the ultrasound results. The width of the tendon was between 0.4 and 0.38 mm. by ultrasound and anatomical analysis. Also, normal palmaris longus tendons were not a direct cause of compression of the median nerve. Conclusions: It is important to confirm the existence and possible variations in the palmaris longus muscle and tendon through ultrasound before surgical reconstruction and for clinical diagnostics.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-01-13
DOI
https://doi.org/10.3390/app16020817
Primary Topic
Peripheral Nerve Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Palmaris Longus Muscle and Its Variations: Ultrasound, Anatomical and Histological Study with Clinical and Surgical Applications

Núria Ruiz-Roig, I. Möller, Sara Ortiz-Miguel, Ana Delgado et al.
Applied Sciences
Peripheral Nerve Disorders
article

Palmaris Longus Muscle and Its Variations: Ultrasound, Anatomical and Histological Study with Clinical and Surgical Applications

Núria Ruiz-Roig, I. Möller, Sara Ortiz-Miguel, Ana Delgado, Albert Pérez‐Bellmunt, Cristina Gallego, Juan Carlos Ortiz-Sagristà, Sandra Lopez-Prades, Maribel Miguel-Pérez
article en

Abstract

Background/objective: The palmaris longus muscle is a variable and often inconsistent muscle in the anterior compartment of the forearm. This fusiform-shaped muscle originates at the medial epicondyle of the humerus bone following a long and narrow tendon that inserts at the palmar aponeurosis. That tendon is used in reconstructive surgery, and for this reason, detailed information from an ultrasound is used to detect the tendon and the possible variations in the muscle. The present study aimed to investigate the palmaris longus muscle and its variations through ultrasound, anatomical, and histological analysis with clinical and surgical applications. Methods: A total of 72 upper limbs from 33 females and 39 males, 32 right and 40 left, were evaluated in ultrasound, anatomical, and histological studies. The main objective was to prove the existence of the palmaris longus muscle and its variations, as well as to measure the tendon for surgical applications. Results: Ultrasound analysis showed that it is possible to determine the existence of the muscle (76.4%) and its variations (23.6%), as well as its absence (15.3%). The anatomical results proved the ultrasound results. The width of the tendon was between 0.4 and 0.38 mm. by ultrasound and anatomical analysis. Also, normal palmaris longus tendons were not a direct cause of compression of the median nerve. Conclusions: It is important to confirm the existence and possible variations in the palmaris longus muscle and tendon through ultrasound before surgical reconstruction and for clinical diagnostics.

Applied SciencesVol. 16(2)
Universitat Autònoma de Barcelona (ES), Bellvitge University Hospital (ES), Hospital Clínic de Barcelona (ES), Centre for Research on Ecology and Forestry Applications (ES), Puigvert Foundation (ES), Consorci Institut D'Investigacions Biomediques August Pi I Sunyer (ES), Universitat de Barcelona (ES), University of Genoa (IT)
Openalex Percentile: Top 90%
Peripheral Nerve Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.