Modeling the mechanical anisotropy in the trabecular bone with the measurement and consideration of the structural anisotropy

The most accurate understanding of the material properties of the trabecular bone tissue of the jawbone is essential for certain oral surgery procedures and for the design of bone replacement materials and implants. The material properties obtained from micro-structural analyses can be used to study the behavior of dental implants and other prostheses implanted in the jawbone. The structural anisotropy of trabecular bone samples from the jawbone was measured using the method of inserted ellipsoids. Using the developed method, it has been shown that bone samples from the close environment of the living tooth-root show anisotropy that can be effectively measured using micro-CT. In this article, we present a method that uses the eigenvalues of the fabric tensor describing structural anisotropy to generate a micro-structural frame model of the trabecular bone. A homogenization method is applied to describe macro-mechanical behavior of the orthotropic bone tissue, which uses the normal-, bending- and torsional stiffness of the beams in the elementary cell in an elastic spring model. With the homogenization of the frame model, the orthotropic material properties of the trabecular bone could be estimated. The method developed is demonstrated using the micro-CT of a bone sample with 0.2636 relative density. The eigenvalues of the fabric tensor of the sample were measured to be 0.5386, 0.3330 and 0.1306, which, after the homogenization of the elementary cell with an identical fabric tensor, resulted in a mechanically orthotropic macro-structure. The apparent moduli obtained were calculated to be 0.6920 GPa, 1.3668 GPa and 0.0503 GPa.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2026-01-13
DOI
https://doi.org/10.1016/j.jmbbm.2026.107345
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling the mechanical anisotropy in the trabecular bone with the measurement and consideration of the structural anisotropy

Róbert K. Németh, Éva I. Lakatos
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Bone health and osteoporosis research
article

Modeling the mechanical anisotropy in the trabecular bone with the measurement and consideration of the structural anisotropy

Róbert K. Németh, Éva I. Lakatos
article en

Abstract

The most accurate understanding of the material properties of the trabecular bone tissue of the jawbone is essential for certain oral surgery procedures and for the design of bone replacement materials and implants. The material properties obtained from micro-structural analyses can be used to study the behavior of dental implants and other prostheses implanted in the jawbone. The structural anisotropy of trabecular bone samples from the jawbone was measured using the method of inserted ellipsoids. Using the developed method, it has been shown that bone samples from the close environment of the living tooth-root show anisotropy that can be effectively measured using micro-CT. In this article, we present a method that uses the eigenvalues of the fabric tensor describing structural anisotropy to generate a micro-structural frame model of the trabecular bone. A homogenization method is applied to describe macro-mechanical behavior of the orthotropic bone tissue, which uses the normal-, bending- and torsional stiffness of the beams in the elementary cell in an elastic spring model. With the homogenization of the frame model, the orthotropic material properties of the trabecular bone could be estimated. The method developed is demonstrated using the micro-CT of a bone sample with 0.2636 relative density. The eigenvalues of the fabric tensor of the sample were measured to be 0.5386, 0.3330 and 0.1306, which, after the homogenization of the elementary cell with an identical fabric tensor, resulted in a mechanically orthotropic macro-structure. The apparent moduli obtained were calculated to be 0.6920 GPa, 1.3668 GPa and 0.0503 GPa.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 176
Budapest University of Technology and Economics (HU)
Openalex Percentile: Top 90%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modeling the mechanical anisotropy in the trabecular bone with the measurement and consideration of the structural anisotropy — Róbert K. Németh, Éva I. Lakatos · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (2026) | TGRS Research Map | TGRS