Tackling Macular Edema and Dislocated Intraocular Lens: The Fluocinolone-loaded IOL With Scleral Suspension (FLISS) Technique

This report presents the fluocinolone-loaded intraocular lens (IOL) with scleral suspension (FLISS) technique as a surgical approach for managing macular edema (ME) in patients with compromised lens-iris diaphragm and dislocated IOL. A 74-year-old woman with a subluxated bag-IOL complex and chronic ME underwent pars plana vitrectomy. After IOL removal, Gore-Tex CV-8 sutures were used to secure a 0.19-mg fluocinolone acetonide (FAc) intravitreal implant (Iluvien) to the haptic of a Micro-pure IOL and subsequently fix the lens to the sclera. Three months later, visual acuity had improved from 20/160 to 20/50, and there was no ME. The FAc implant remained stable and well positioned outside the visual axis. The FLISS technique, herein described for the first time, offers a promising alternative for addressing chronic ME in eyes requiring secondary IOL implantation, with the benefits of no additional scleral manipulation (compared to standard IOL scleral fixation) and low risk of implant migration.

Authors

Institutions

Publication Details

Journal
Ophthalmic surgery, lasers & imaging retina
Published
2026-01-13
DOI
https://doi.org/10.3928/23258160-20251203-01
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tackling Macular Edema and Dislocated Intraocular Lens: The Fluocinolone-loaded IOL With Scleral Suspension (FLISS) Technique

Joana Braga, Miguel Bilhoto, P. Martins, João Castro Cabanas et al.
Ophthalmic surgery, lasers & imaging retina
Intraocular Surgery and Lenses
article

Tackling Macular Edema and Dislocated Intraocular Lens: The Fluocinolone-loaded IOL With Scleral Suspension (FLISS) Technique

Joana Braga, Miguel Bilhoto, P. Martins, João Castro Cabanas, Paula A. Sepúlveda, Filipe Sousa-Neves
article en

Abstract

This report presents the fluocinolone-loaded intraocular lens (IOL) with scleral suspension (FLISS) technique as a surgical approach for managing macular edema (ME) in patients with compromised lens-iris diaphragm and dislocated IOL. A 74-year-old woman with a subluxated bag-IOL complex and chronic ME underwent pars plana vitrectomy. After IOL removal, Gore-Tex CV-8 sutures were used to secure a 0.19-mg fluocinolone acetonide (FAc) intravitreal implant (Iluvien) to the haptic of a Micro-pure IOL and subsequently fix the lens to the sclera. Three months later, visual acuity had improved from 20/160 to 20/50, and there was no ME. The FAc implant remained stable and well positioned outside the visual axis. The FLISS technique, herein described for the first time, offers a promising alternative for addressing chronic ME in eyes requiring secondary IOL implantation, with the benefits of no additional scleral manipulation (compared to standard IOL scleral fixation) and low risk of implant migration.

Ophthalmic surgery, lasers & imaging retinaVol. 57(2)
Administração Regional de Saúde de Lisboa e Vale do Tejo (PT)
Gender equality
Openalex Percentile: Top 89%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.