Thermodynamic analysis of a novel radial-flow cryogenic packed bed for liquid air energy storage

• A novel radial-flow cryogenic packed bed is proposed for large-scale LAES systems. • The radial-flow design reduces pressure drop to 1173 Pa, ∼15 times lower than axial-flow beds. • It achieves an exergy efficiency of 87.7%, 7.1% higher than axial-flow configuration. • Optimal configuration is achieved for the proposed radial-flow cryogenic packed bed. With the rapid penetration of renewable energy in power grid, the necessity for large-scale, long-duration energy storage technologies has become increasingly evident to enhance grid flexibility. Liquid air energy storage (LAES) has emerged as a promising option, where cryogenic energy storage plays a decisive role in round-trip efficiency of the LAES. The traditional method uses axial-flow packed beds to store cryogenic energy, which suffers from large pressure drops, high pumping work consumption and low exergy efficiency. To address the above issues, this paper proposes a novel radial-flow packed bed for a 10 MW/80 MWh LAES system. Systematic analyses are made on the radial-flow packed bed in terms of bed volume, aspect ratio, inner channel ratio, and particle size. Results show that the radial-flow cryogenic packed bed achieves a higher exergy efficiency of 87.7% compared to that of axial-flow packed bed (80.6%). This is because of the much lower pressure drops of radial-flow packed bed (1,173 Pa), where the axial-flow packed bed has a larger pressure drop of 17,186 Pa. Parametric studies further reveal that optimal performance is obtained at 1.5 times the volume of reference bed volume, aspect ratio of 0.1, and inner channel ratios of 0.20–0.25. Particle size reduction enhances heat transfer but significantly increases pressure losses. These findings demonstrate that radial-flow cryogenic packed bed is more energy efficient and applicable for large-scale LAES system.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2026-01-13
DOI
https://doi.org/10.1016/j.enconman.2025.121026
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermodynamic analysis of a novel radial-flow cryogenic packed bed for liquid air energy storage

Xingyu Wang, C. Y. Wang, Ziao Zhang, Xiaohui She et al.
Energy Conversion and Management
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Thermodynamic analysis of a novel radial-flow cryogenic packed bed for liquid air energy storage

Xingyu Wang, C. Y. Wang, Ziao Zhang, Xiaohui She, Yulong Ding
article en

Abstract

• A novel radial-flow cryogenic packed bed is proposed for large-scale LAES systems. • The radial-flow design reduces pressure drop to 1173 Pa, ∼15 times lower than axial-flow beds. • It achieves an exergy efficiency of 87.7%, 7.1% higher than axial-flow configuration. • Optimal configuration is achieved for the proposed radial-flow cryogenic packed bed. With the rapid penetration of renewable energy in power grid, the necessity for large-scale, long-duration energy storage technologies has become increasingly evident to enhance grid flexibility. Liquid air energy storage (LAES) has emerged as a promising option, where cryogenic energy storage plays a decisive role in round-trip efficiency of the LAES. The traditional method uses axial-flow packed beds to store cryogenic energy, which suffers from large pressure drops, high pumping work consumption and low exergy efficiency. To address the above issues, this paper proposes a novel radial-flow packed bed for a 10 MW/80 MWh LAES system. Systematic analyses are made on the radial-flow packed bed in terms of bed volume, aspect ratio, inner channel ratio, and particle size. Results show that the radial-flow cryogenic packed bed achieves a higher exergy efficiency of 87.7% compared to that of axial-flow packed bed (80.6%). This is because of the much lower pressure drops of radial-flow packed bed (1,173 Pa), where the axial-flow packed bed has a larger pressure drop of 17,186 Pa. Parametric studies further reveal that optimal performance is obtained at 1.5 times the volume of reference bed volume, aspect ratio of 0.1, and inner channel ratios of 0.20–0.25. Particle size reduction enhances heat transfer but significantly increases pressure losses. These findings demonstrate that radial-flow cryogenic packed bed is more energy efficient and applicable for large-scale LAES system.

Energy Conversion and ManagementVol. 351
University of Birmingham (GB), Shijiazhuang Tiedao University (CN)
Affordable and clean energy
Openalex Percentile: Top 89%
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.