Research on the method for measuring the focal spot size of micro-focus X-ray sources using the JIMA resolution test card

BackgroundMeasuring an X-ray source's focal spot size is vital for Micro-CT resolution. Standard methods are often too complex or inaccurate. The popular JIMA resolution test card is simple to use but lacks a clear, quantitative formula to determine the actual focal spot size.ObjectiveThis study aims to create a reliable quantitative link between JIMA resolution and focal spot size using simulations and experiments.MethodsWe used Monte Carlo simulations and practical experiments to establish the relationship between JIMA resolution and focal spot size.ResultsWe found that the focal spot size is twice the line pair width on the JIMA card when the image contrast (MTF) is at 10%. This method is highly accurate, with a maximum measurement error of less than 8.7% compared to a high-precision technique.ConclusionsOur findings provide a simple, fast, and validated method for measuring focal spot size using the JIMA test card. This makes it a practical and reliable alternative to more complex procedures.

Authors

Institutions

Publication Details

Journal
Journal of X-Ray Science and Technology
Published
2026-01-13
DOI
https://doi.org/10.1177/08953996251403456
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on the method for measuring the focal spot size of micro-focus X-ray sources using the JIMA resolution test card

Fengxiao Li, Zhou Rifeng, Liu Chengfeng, Yixin Wang et al.
Journal of X-Ray Science and Technology
Advanced X-ray and CT Imaging
article

Research on the method for measuring the focal spot size of micro-focus X-ray sources using the JIMA resolution test card

Fengxiao Li, Zhou Rifeng, Liu Chengfeng, Yixin Wang, Zhong Guowei, Yang Run, Xu Haodong
article en

Abstract

BackgroundMeasuring an X-ray source's focal spot size is vital for Micro-CT resolution. Standard methods are often too complex or inaccurate. The popular JIMA resolution test card is simple to use but lacks a clear, quantitative formula to determine the actual focal spot size.ObjectiveThis study aims to create a reliable quantitative link between JIMA resolution and focal spot size using simulations and experiments.MethodsWe used Monte Carlo simulations and practical experiments to establish the relationship between JIMA resolution and focal spot size.ResultsWe found that the focal spot size is twice the line pair width on the JIMA card when the image contrast (MTF) is at 10%. This method is highly accurate, with a maximum measurement error of less than 8.7% compared to a high-precision technique.ConclusionsOur findings provide a simple, fast, and validated method for measuring focal spot size using the JIMA test card. This makes it a practical and reliable alternative to more complex procedures.

Journal of X-Ray Science and Technology
Chongqing University (CN), Chongqing University of Technology (CN)
Openalex Percentile: Top 90%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on the method for measuring the focal spot size of micro-focus X-ray sources using the JIMA resolution test card — Fengxiao Li, Zhou Rifeng, et al. · Journal of X-Ray Science and Technology (2026) | TGRS Research Map | TGRS