Reflective Zone Plate as a Tool for Characterizing a Laser-Plasma Source of Soft X-Rays

A grazing-incidence reflective zone plate is designed for operation at a wavelength of 135 Å in the first diffraction order, at a wavelength of 67.5 Å in the second order, and so on. A spectrometer with a reflective zone plate with a flat field in the 125–235 Å rang is proposed. Using numerical ray tracing, the spectral image of a point source is calculated at wavelengths of 135 and 135.1 Å, as well as 125, 125.1, 130, 130.1, 140, 140.1, and 145, 145.1 Å. It is shown that the spectral resolution in the flat field region exceeds 103, and the spatial resolution in the crossed direction at the selected wavelength of 135 Å is no worse than 1 μm. The reflective zone plate is an effective tool for diagnosing the spatial and spectral parameters of a laser-plasma soft X-ray source.

Authors

Institutions

Publication Details

Journal
Bulletin of the Lebedev Physics Institute
Published
2025-12-01
DOI
https://doi.org/10.3103/s1068335625603930
Primary Topic
Laser-Plasma Interactions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reflective Zone Plate as a Tool for Characterizing a Laser-Plasma Source of Soft X-Rays

A. N. Firsov, A. O. Kolesnikov, A. N. Shatokhin, E. N. Ragozin
Bulletin of the Lebedev Physics Institute
Laser-Plasma Interactions and Diagnostics
article

Reflective Zone Plate as a Tool for Characterizing a Laser-Plasma Source of Soft X-Rays

A. N. Firsov, A. O. Kolesnikov, A. N. Shatokhin, E. N. Ragozin
article en

Abstract

A grazing-incidence reflective zone plate is designed for operation at a wavelength of 135 Å in the first diffraction order, at a wavelength of 67.5 Å in the second order, and so on. A spectrometer with a reflective zone plate with a flat field in the 125–235 Å rang is proposed. Using numerical ray tracing, the spectral image of a point source is calculated at wavelengths of 135 and 135.1 Å, as well as 125, 125.1, 130, 130.1, 140, 140.1, and 145, 145.1 Å. It is shown that the spectral resolution in the flat field region exceeds 103, and the spatial resolution in the crossed direction at the selected wavelength of 135 Å is no worse than 1 μm. The reflective zone plate is an effective tool for diagnosing the spatial and spectral parameters of a laser-plasma soft X-ray source.

Bulletin of the Lebedev Physics InstituteVol. 52(S8)
P.N. Lebedev Physical Institute of the Russian Academy of Sciences (RU), Kurchatov Institute (RU)
Openalex Percentile: Top 20%
Laser-Plasma Interactions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reflective Zone Plate as a Tool for Characterizing a Laser-Plasma Source of Soft X-Rays — A. N. Firsov, A. O. Kolesnikov, et al. · Bulletin of the Lebedev Physics Institute (2025) | TGRS Research Map | TGRS