<b>Objective:</b> Mobile head CT enables bedside neuroimaging in critically ill patients, reducing risks associated with intrahospital transport. Despite increasing clinical use, evidence on dose optimization for mobile CT systems remains limited. This study evaluated whether an optimized CT protocol can reduce radiation exposure without compromising diagnostic image quality in neurointensive care unit patients. <b>Methods:</b> In this retrospective single-center study, twenty-two non-contrast head CT examinations were acquired with a second-generation mobile CT scanner between March and May 2023. Patients underwent either a default (group A, <i>n</i> = 14; volumetric computed tomography dose index (CTDI<sub>vol</sub>) 44.1 mGy) or low-dose CT protocol (group B, <i>n</i> = 8; CTDI<sub>vol</sub> 32.1 mGy). Regarding dosimetry analysis, we recorded dose length product (DLP) and effective dose (ED). Quantitative image quality was assessed by manually placing ROIs at the basal ganglia and cerebellar levels to determine signal, noise, signal-to-noise ratio, and contrast-to-noise ratio. Two neuroradiologists independently rated qualitative image quality using a four-point Likert scale. Statistical comparisons were performed using a significance threshold of 0.05. <b>Results:</b> Median DLP and ED were significantly lower for group B (592 mGy·cm, 1.12 mSv) than for group A (826 mGy·cm, 1.57 mSv; each <i>p</i> < 0.0001). Quantitative image quality parameters did not differ significantly between groups (<i>p</i> > 0.05). Qualitative image quality was rated excellent (median score 4). <b>Conclusions:</b> The optimized mobile head CT protocol achieved a 28.7% reduction in radiation exposure while maintaining high diagnostic image quality. These findings support the adoption of low-dose strategies in mobile CT imaging in line with established radiation protection standards.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-01-13
DOI
https://doi.org/10.3390/diagnostics16020256
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Balancing Radiation Dose and Image Quality: Protocol Optimization for Mobile Head CT in Neurointensive Care Unit Patients

R Forbrig, Tim Wesemann, Thomas Fischer, Robert Stahl et al.
Diagnostics
Radiation Dose and Imaging
article

Balancing Radiation Dose and Image Quality: Protocol Optimization for Mobile Head CT in Neurointensive Care Unit Patients

R Forbrig, Tim Wesemann, Thomas Fischer, Robert Stahl, Thomas Liebig, K Dimitriadis, Suzette Heck, Christoph Trumm, Damian Luka Mialkowskyj
article en

Abstract

<b>Objective:</b> Mobile head CT enables bedside neuroimaging in critically ill patients, reducing risks associated with intrahospital transport. Despite increasing clinical use, evidence on dose optimization for mobile CT systems remains limited. This study evaluated whether an optimized CT protocol can reduce radiation exposure without compromising diagnostic image quality in neurointensive care unit patients. <b>Methods:</b> In this retrospective single-center study, twenty-two non-contrast head CT examinations were acquired with a second-generation mobile CT scanner between March and May 2023. Patients underwent either a default (group A, <i>n</i> = 14; volumetric computed tomography dose index (CTDI<sub>vol</sub>) 44.1 mGy) or low-dose CT protocol (group B, <i>n</i> = 8; CTDI<sub>vol</sub> 32.1 mGy). Regarding dosimetry analysis, we recorded dose length product (DLP) and effective dose (ED). Quantitative image quality was assessed by manually placing ROIs at the basal ganglia and cerebellar levels to determine signal, noise, signal-to-noise ratio, and contrast-to-noise ratio. Two neuroradiologists independently rated qualitative image quality using a four-point Likert scale. Statistical comparisons were performed using a significance threshold of 0.05. <b>Results:</b> Median DLP and ED were significantly lower for group B (592 mGy·cm, 1.12 mSv) than for group A (826 mGy·cm, 1.57 mSv; each <i>p</i> < 0.0001). Quantitative image quality parameters did not differ significantly between groups (<i>p</i> > 0.05). Qualitative image quality was rated excellent (median score 4). <b>Conclusions:</b> The optimized mobile head CT protocol achieved a 28.7% reduction in radiation exposure while maintaining high diagnostic image quality. These findings support the adoption of low-dose strategies in mobile CT imaging in line with established radiation protection standards.

DiagnosticsVol. 16(2)
University Hospital Augsburg (DE), LMU Klinikum (DE), Ludwig-Maximilians-Universität München (DE)
Good health and well-being
Openalex Percentile: Top 90%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.