Comparison of Real-Time and Offline Mass Spectrometry Methods for Quantitation of Fluorotelomer Alcohols in Aqueous Film-Forming Foam Headspace

Per- and polyfluoroalkyl substances (PFAS) are highly water-, grease-, and heat-resistant compounds known as "forever chemicals" due to their resistance to degradation. Aqueous film-forming foams (AFFFs) are PFAS-containing firefighting foams and a known source of environmental PFAS contamination. Recent research characterizing PFAS contamination at historical AFFF usage sites has advanced our understanding of environmental fate and transport of water-soluble PFAS. However, emissions of volatile or semivolatile PFAS from AFFFs during their storage and application and from AFFF-contaminated sites remain largely uncharacterized, in part due to analytical method limitations. This work quantified fluorotelomer alcohols (FTOHs) in the headspace above three AFFF formulations using two emerging analytical techniques: thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) and real-time iodide chemical ionization mass spectrometry (I-CIMS). Thermal desorption tube samples were collected for offline analysis via TD-GC/MS, while I-CIMS simultaneously sampled the headspace. Then, the FTOH headspace concentrations quantified by the two techniques were compared. In all three formulations, 6:2 and 8:2 FTOHs were the most and second-most abundant, respectively. The FTOH concentrations quantified by TD-GC/MS ranged from 0.06 to 2.0 μg/m<sup>3</sup>, while those quantified by I-CIMS ranged from 0.13 to 4.4 μg/m<sup>3</sup>. The percent error between the two methods ranged from 10 to 102%. These results underscore the need for additional research exploring the factors that impact the quantitative accuracy of both methods.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-01-13
DOI
https://doi.org/10.1021/jasms.5c00298
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Real-Time and Offline Mass Spectrometry Methods for Quantitation of Fluorotelomer Alcohols in Aqueous Film-Forming Foam Headspace

William R. Roberson, Melinda K. Schueneman, Kenneth S. Docherty, Gabrielle V. West et al.
Journal of the American Society for Mass Spectrometry
Per- and polyfluoroalkyl substances research
article

Comparison of Real-Time and Offline Mass Spectrometry Methods for Quantitation of Fluorotelomer Alcohols in Aqueous Film-Forming Foam Headspace

William R. Roberson, Melinda K. Schueneman, Kenneth S. Docherty, Gabrielle V. West, M. Ariel Geer Wallace, Jonathan D. Krug, Matthew S. Clifton
article en

Abstract

Per- and polyfluoroalkyl substances (PFAS) are highly water-, grease-, and heat-resistant compounds known as "forever chemicals" due to their resistance to degradation. Aqueous film-forming foams (AFFFs) are PFAS-containing firefighting foams and a known source of environmental PFAS contamination. Recent research characterizing PFAS contamination at historical AFFF usage sites has advanced our understanding of environmental fate and transport of water-soluble PFAS. However, emissions of volatile or semivolatile PFAS from AFFFs during their storage and application and from AFFF-contaminated sites remain largely uncharacterized, in part due to analytical method limitations. This work quantified fluorotelomer alcohols (FTOHs) in the headspace above three AFFF formulations using two emerging analytical techniques: thermal desorption-gas chromatography/mass spectrometry (TD-GC/MS) and real-time iodide chemical ionization mass spectrometry (I-CIMS). Thermal desorption tube samples were collected for offline analysis via TD-GC/MS, while I-CIMS simultaneously sampled the headspace. Then, the FTOH headspace concentrations quantified by the two techniques were compared. In all three formulations, 6:2 and 8:2 FTOHs were the most and second-most abundant, respectively. The FTOH concentrations quantified by TD-GC/MS ranged from 0.06 to 2.0 μg/m<sup>3</sup>, while those quantified by I-CIMS ranged from 0.13 to 4.4 μg/m<sup>3</sup>. The percent error between the two methods ranged from 10 to 102%. These results underscore the need for additional research exploring the factors that impact the quantitative accuracy of both methods.

Journal of the American Society for Mass SpectrometryVol. 37(2)
University of North Carolina at Chapel Hill (US), Environmental Protection Agency (US)
Clean water and sanitation
Openalex Percentile: Top 91%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.