Multiple amplitude wavelength modulation spectroscopy for concomitant measurement of pressure and concentration of methane

A novel technique based on multiple amplitude wavelength modulation spectroscopy (MA-WMS) for simultaneous measurement of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msub><mml:mtext>CH</mml:mtext> <mml:mn>4</mml:mn></mml:msub> </mml:math> gas concentration and pressure was developed and validated both through simulation and experiment, showing good agreement. To capture the spectrum broadening caused by increasing pressure and concomitantly obtain the concentration at the sensor's location, a laser centered at 1650.9 nm was subjected to multiple amplitude modulation depths while the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>2</mml:mn> <mml:msub><mml:mi>f</mml:mi> <mml:mi>m</mml:mi></mml:msub> </mml:mrow> </mml:math> signal, normalized by the DC component (an invariant quantity under optical loss), was recorded. While the use of a single and fixed modulation can introduce an ambiguity, as different pairs of pressure and concentration can yield the same value, this ambiguity is eliminated by employing multiple amplitude modulations. In this approach, the intersection point of the three level curves can provide the local pressure and concentration. The proposed system was able to measure concentrations from 5% up to 45% and pressures from 0.25 atm up to 1.75 atm, with a maximum error of 2% in concentration and 0.06 atm in pressure, respectively. The system was also tested for attenuation insensitivity, demonstrating that measurements were not significantly affected for up to 10 dB applied optical loss.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-13
DOI
https://doi.org/10.1038/s41598-025-32958-z
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple amplitude wavelength modulation spectroscopy for concomitant measurement of pressure and concentration of methane

Claudio Floridia, Lorenzo Santini, Luís C. C. Coelho
Scientific Reports
Spectroscopy and Laser Applications
article

Multiple amplitude wavelength modulation spectroscopy for concomitant measurement of pressure and concentration of methane

Claudio Floridia, Lorenzo Santini, Luís C. C. Coelho
article en

Abstract

A novel technique based on multiple amplitude wavelength modulation spectroscopy (MA-WMS) for simultaneous measurement of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msub><mml:mtext>CH</mml:mtext> <mml:mn>4</mml:mn></mml:msub> </mml:math> gas concentration and pressure was developed and validated both through simulation and experiment, showing good agreement. To capture the spectrum broadening caused by increasing pressure and concomitantly obtain the concentration at the sensor's location, a laser centered at 1650.9 nm was subjected to multiple amplitude modulation depths while the <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:mn>2</mml:mn> <mml:msub><mml:mi>f</mml:mi> <mml:mi>m</mml:mi></mml:msub> </mml:mrow> </mml:math> signal, normalized by the DC component (an invariant quantity under optical loss), was recorded. While the use of a single and fixed modulation can introduce an ambiguity, as different pairs of pressure and concentration can yield the same value, this ambiguity is eliminated by employing multiple amplitude modulations. In this approach, the intersection point of the three level curves can provide the local pressure and concentration. The proposed system was able to measure concentrations from 5% up to 45% and pressures from 0.25 atm up to 1.75 atm, with a maximum error of 2% in concentration and 0.06 atm in pressure, respectively. The system was also tested for attenuation insensitivity, demonstrating that measurements were not significantly affected for up to 10 dB applied optical loss.

Scientific ReportsVol. 16(1)
Universidade do Porto (PT), INESC TEC (PT)
European Commission, Fundação para a Ciência e a Tecnologia
Openalex Percentile: Top 90%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.