Quantum weak measurement biosensor for label-free drug-to-antibody ratio determination of T-DXd

Antibody-drug conjugates (ADCs) demand precise drug-to-antibody ratio (DAR) characterization to ensure therapeutic efficacy, safety, and regulatory compliance. However, conventional DAR methods such as UV-Vis spectroscopy, hydrophobic interaction chromatography, and mass spectrometry are often destructive, label-dependent, or incapable of real-time analysis under physiologically relevant conditions. Here, we present a quantum weak measurement (QWM)-based Mach-Zehnder interferometric biosensor that enables label-free in-vitro DAR quantification of trastuzumab deruxtecan (T-DXd) on fixed human epidermal growth factor receptor 2 (HER2)-overexpressing SKBR3 cell substrates. Weak-value amplification enhances the phase sensitivity of the interferometer, allowing picomolar-level detection of T-DXd and real-time monitoring of HER2-targeted binding and dithiothreitol-induced DXd payload release within a unified optical platform. Calibration experiments yield an excellent linear response with a sensitivity of 3.166 × 10<sup>10</sup>nm · M<sup>-1</sup> and a detection limit of 1.31 × 10<sup>-12</sup>M. By combining T-DXd adsorption and DXd release measurements, the QWM sensor determines a DAR of (7.3 ± 0.26), in good agreement with nominal specifications. The interferometric readout operates without fluorescent or enzymatic labels and avoids harsh digestion of the antibody scaffold, while requiring only microliter-scale sample volumes. Beyond T-DXd, this modular quantum biosensing architecture is adaptable to other ADCs and protein-drug conjugates as a complementary tool for precision biopharmaceutical characterization and quality control.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2026-01-12
DOI
https://doi.org/10.1364/oe.583299
Primary Topic
HER2/EGFR in Cancer Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantum weak measurement biosensor for label-free drug-to-antibody ratio determination of T-DXd

Yufei Liu, YI RUAN, Jingjing Zhang, Dongmei Li et al.
Optics Express
HER2/EGFR in Cancer Research
article

Quantum weak measurement biosensor for label-free drug-to-antibody ratio determination of T-DXd

Yufei Liu, YI RUAN, Jingjing Zhang, Dongmei Li, Jia Yao, Qiang Lin, Shuqian Wang
article en

Abstract

Antibody-drug conjugates (ADCs) demand precise drug-to-antibody ratio (DAR) characterization to ensure therapeutic efficacy, safety, and regulatory compliance. However, conventional DAR methods such as UV-Vis spectroscopy, hydrophobic interaction chromatography, and mass spectrometry are often destructive, label-dependent, or incapable of real-time analysis under physiologically relevant conditions. Here, we present a quantum weak measurement (QWM)-based Mach-Zehnder interferometric biosensor that enables label-free in-vitro DAR quantification of trastuzumab deruxtecan (T-DXd) on fixed human epidermal growth factor receptor 2 (HER2)-overexpressing SKBR3 cell substrates. Weak-value amplification enhances the phase sensitivity of the interferometer, allowing picomolar-level detection of T-DXd and real-time monitoring of HER2-targeted binding and dithiothreitol-induced DXd payload release within a unified optical platform. Calibration experiments yield an excellent linear response with a sensitivity of 3.166 × 10<sup>10</sup>nm · M<sup>-1</sup> and a detection limit of 1.31 × 10<sup>-12</sup>M. By combining T-DXd adsorption and DXd release measurements, the QWM sensor determines a DAR of (7.3 ± 0.26), in good agreement with nominal specifications. The interferometric readout operates without fluorescent or enzymatic labels and avoids harsh digestion of the antibody scaffold, while requiring only microliter-scale sample volumes. Beyond T-DXd, this modular quantum biosensing architecture is adaptable to other ADCs and protein-drug conjugates as a complementary tool for precision biopharmaceutical characterization and quality control.

Optics ExpressVol. 34(2)
Westlake University (CN), Zhejiang University (CN)
Openalex Percentile: Top 89%
HER2/EGFR in Cancer Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantum weak measurement biosensor for label-free drug-to-antibody ratio determination of T-DXd — Yufei Liu, YI RUAN, et al. · Optics Express (2026) | TGRS Research Map | TGRS