Research on Friction Welded Connections of B500SP Reinforcement Bars with 1.4301 (AISI 304) and 1.4021 (AISI 420) Stainless Steel Bars

Steel and prestressed concrete traction poles can be fixed to reinforced concrete pile foundations using typical bolted connections. The stainless steel fastening screw is connected to the ordinary steel foundation pile reinforcement by friction welding under specific friction welding process parameters. From the perspective of the structural strength of the connection between the traction pole and the foundation pile, regarding the transfer of tensile and shear forces through a single anchor bolt, the yield strength of stainless steel bolts should be R<sub>e,min</sub> ≥ 345 MPa for M30 anchors, R<sub>e,min</sub> ≥ 310 MPa for M36 anchors and R<sub>e,min</sub> ≥ 300 MPa for M42 anchors. This requirement is reliably met by martensitic stainless steels, while other stainless steels have yield strengths below the required minimum. What truly determines the foundation pile's load capacity is not the satisfactory mechanical strength of the stainless steel (here, the parameters are met), but the quality of the friction-welded end connection between the reinforcement and the threaded bars. Incorrect selection of the type of prestressing steel in the analyzed connection can have enormous consequences for foundation pile manufacturers. Annual production of foundation piles amounts to thousands of units, and an incorrect decision made by the pile designer at the design stage can result in significant financial losses and a high risk to human life. This article presents the results of studies on friction-welded connections of M30, M36, and M42 threaded bars made of austenitic 1.4301 (AISI 304) and martensitic 1.4021 (AISI 420) stainless steel with B500SP reinforcement bars. The tests yielded negative results for 1.4021 (AISI 420) steel, despite its yield strength exceeding R<sub>e</sub> ≥ 360 MPa.

Authors

Institutions

Publication Details

Journal
Materials
Published
2026-01-13
DOI
https://doi.org/10.3390/ma19020313
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Friction Welded Connections of B500SP Reinforcement Bars with 1.4301 (AISI 304) and 1.4021 (AISI 420) Stainless Steel Bars

J. Michałek, R. Krawczyk
Materials
Structural Load-Bearing Analysis
article

Research on Friction Welded Connections of B500SP Reinforcement Bars with 1.4301 (AISI 304) and 1.4021 (AISI 420) Stainless Steel Bars

J. Michałek, R. Krawczyk
article en

Abstract

Steel and prestressed concrete traction poles can be fixed to reinforced concrete pile foundations using typical bolted connections. The stainless steel fastening screw is connected to the ordinary steel foundation pile reinforcement by friction welding under specific friction welding process parameters. From the perspective of the structural strength of the connection between the traction pole and the foundation pile, regarding the transfer of tensile and shear forces through a single anchor bolt, the yield strength of stainless steel bolts should be R<sub>e,min</sub> ≥ 345 MPa for M30 anchors, R<sub>e,min</sub> ≥ 310 MPa for M36 anchors and R<sub>e,min</sub> ≥ 300 MPa for M42 anchors. This requirement is reliably met by martensitic stainless steels, while other stainless steels have yield strengths below the required minimum. What truly determines the foundation pile's load capacity is not the satisfactory mechanical strength of the stainless steel (here, the parameters are met), but the quality of the friction-welded end connection between the reinforcement and the threaded bars. Incorrect selection of the type of prestressing steel in the analyzed connection can have enormous consequences for foundation pile manufacturers. Annual production of foundation piles amounts to thousands of units, and an incorrect decision made by the pile designer at the design stage can result in significant financial losses and a high risk to human life. This article presents the results of studies on friction-welded connections of M30, M36, and M42 threaded bars made of austenitic 1.4301 (AISI 304) and martensitic 1.4021 (AISI 420) stainless steel with B500SP reinforcement bars. The tests yielded negative results for 1.4021 (AISI 420) steel, despite its yield strength exceeding R<sub>e</sub> ≥ 360 MPa.

MaterialsVol. 19(2)
Wrocław University of Science and Technology (PL), Częstochowa University of Technology (PL), AGH University of Krakow (PL)
Openalex Percentile: Top 89%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.