Calibrated Transformer Fusion for Dual-View Low-Energy CESM Classification

Contrast-enhanced spectral mammography (CESM) provides low-energy images acquired in standard craniocaudal (CC) and mediolateral oblique (MLO) views, and clinical interpretation relies on integrating both views. This study proposes a dual-view classification framework that combines deep CNN feature extraction with transformer-based fusion for breast-side classification using low-energy (DM) images from CESM acquisitions (Normal vs. Tumorous; benign and malignant merged). The evaluation was conducted using 5-fold stratified group cross-validation with patient-level grouping to prevent leakage across folds. The final configuration (Model E) integrates dual-backbone feature extraction, transformer fusion, MC-dropout inference for uncertainty estimation, and post hoc logistic calibration. Across the five held-out test folds, Model E achieved a mean accuracy of 96.88% ± 2.39% and a mean F1-score of 97.68% ± 1.66%. The mean ROC-AUC and PR-AUC were 0.9915 ± 0.0098 and 0.9968 ± 0.0029, respectively. Probability quality was supported by a mean Brier score of 0.0236 ± 0.0145 and a mean expected calibration error (ECE) of 0.0334 ± 0.0171. An ablation study (Models A-E) was also reported to quantify the incremental contribution of dual-view input, transformer fusion, and uncertainty calibration. Within the limits of this retrospective single-center setting, these results suggest that dual-view transformer fusion can provide strong discrimination while also producing calibrated probabilities and uncertainty outputs that are relevant for decision support.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2026-01-13
DOI
https://doi.org/10.3390/jimaging12010041
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibrated Transformer Fusion for Dual-View Low-Energy CESM Classification

Ahmed Alkurdi
Journal of Imaging
Digital Radiography and Breast Imaging
article

Calibrated Transformer Fusion for Dual-View Low-Energy CESM Classification

Ahmed Alkurdi
article en

Abstract

Contrast-enhanced spectral mammography (CESM) provides low-energy images acquired in standard craniocaudal (CC) and mediolateral oblique (MLO) views, and clinical interpretation relies on integrating both views. This study proposes a dual-view classification framework that combines deep CNN feature extraction with transformer-based fusion for breast-side classification using low-energy (DM) images from CESM acquisitions (Normal vs. Tumorous; benign and malignant merged). The evaluation was conducted using 5-fold stratified group cross-validation with patient-level grouping to prevent leakage across folds. The final configuration (Model E) integrates dual-backbone feature extraction, transformer fusion, MC-dropout inference for uncertainty estimation, and post hoc logistic calibration. Across the five held-out test folds, Model E achieved a mean accuracy of 96.88% ± 2.39% and a mean F1-score of 97.68% ± 1.66%. The mean ROC-AUC and PR-AUC were 0.9915 ± 0.0098 and 0.9968 ± 0.0029, respectively. Probability quality was supported by a mean Brier score of 0.0236 ± 0.0145 and a mean expected calibration error (ECE) of 0.0334 ± 0.0171. An ablation study (Models A-E) was also reported to quantify the incremental contribution of dual-view input, transformer fusion, and uncertainty calibration. Within the limits of this retrospective single-center setting, these results suggest that dual-view transformer fusion can provide strong discrimination while also producing calibrated probabilities and uncertainty outputs that are relevant for decision support.

Journal of ImagingVol. 12(1)
Duhok Polytechnic University (IQ), Southern Technical University (IQ)
Peace, Justice and strong institutions
Openalex Percentile: Top 90%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Calibrated Transformer Fusion for Dual-View Low-Energy CESM Classification — Ahmed Alkurdi · Journal of Imaging (2026) | TGRS Research Map | TGRS