Prospective, non-randomized, controlled investigation of prostate (P) artery embolization (E) compared to holmium (Ho) laser enucleation of prostate for the treatment of symptomatic benign prostatic hyperplasia with prostate volume 80–250 cc: the hop

To compare outcomes of Prostate Artery Embolization (PAE) with Holmium Laser Enucleation of Prostate (HoLEP) for management of symptomatic benign prostate hyperplasia in men with prostate volume 80 to 250 cc. In this open-label prospective clinical-trial, 45 patients were enrolled in a 2:1 ratio to undergo PAE and HoLEP, respectively. The voiding parameter, sexual function, and complications were evaluated at 1, 3, 6, and 12-months. The primary endpoint was a reduction in the International Prostate Symptom Score (IPSS) at 3 months. Secondary-outcomes were change in the International Index of Erectile Function-15 (IIEF-15), International Consultation on Incontinence Questionnaire-urinary incontinence (ICIQ-UI), Quality-of-Life (QoL), IPSS, uroflow (Qmax) and Prostate Specific Antigen (PSA). Adverse-events were recorded and graded using the Clavien–Dindo Adverse-event (CD-AE) classification. No significant difference in median IPSS and quality of life improvement was observed at any follow-up point. PAE had significantly better IIEF-15 and ICIQ-UI outcomes than HoLEP at 1 and 3 months. HoLEP outperformed PAE in PSA reduction, Qmax, and post-void residual (PVR) improvement at 3 and 12-months. However, PAE had shorter hospital stays and avoided catheterization. No major adverse events (Clavien–Dindo ≥ grade 3) occurred in either group. In men with BPH and prostate sizes 80–250gm, PAE and HoLEP produce similar IPSS and QoL improvement at medium-term follow-up. PAE had better IIEF-15 and ICIQ-UI, in addition to the advantage of avoiding catheterization and reduced hospital stay. HoLEP performed better in PSA reduction, Qmax, and PVR improvement at 3 and 12 months. No serious adverse events occurred in either treatment group. Small sample size and short-term follow-up were important limitations.

Authors

Institutions

Publication Details

Journal
World Journal of Urology
Published
2026-01-13
DOI
https://doi.org/10.1007/s00345-025-06115-0
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective, non-randomized, controlled investigation of prostate (P) artery embolization (E) compared to holmium (Ho) laser enucleation of prostate for the treatment of symptomatic benign prostatic hyperplasia with prostate volume 80–250 cc: the hop

Andrew David Richardson, Hemendra Shah, Joao G. Porto, Chloe Issa et al.
World Journal of Urology
Urinary Bladder and Prostate Research
article

Prospective, non-randomized, controlled investigation of prostate (P) artery embolization (E) compared to holmium (Ho) laser enucleation of prostate for the treatment of symptomatic benign prostatic hyperplasia with prostate volume 80–250 cc: the hop

Andrew David Richardson, Hemendra Shah, Joao G. Porto, Chloe Issa, Shivank Bhatia, Kenneth Richardson, Ansh Bhatia, Muhammad U. Shahid
article en

Abstract

To compare outcomes of Prostate Artery Embolization (PAE) with Holmium Laser Enucleation of Prostate (HoLEP) for management of symptomatic benign prostate hyperplasia in men with prostate volume 80 to 250 cc. In this open-label prospective clinical-trial, 45 patients were enrolled in a 2:1 ratio to undergo PAE and HoLEP, respectively. The voiding parameter, sexual function, and complications were evaluated at 1, 3, 6, and 12-months. The primary endpoint was a reduction in the International Prostate Symptom Score (IPSS) at 3 months. Secondary-outcomes were change in the International Index of Erectile Function-15 (IIEF-15), International Consultation on Incontinence Questionnaire-urinary incontinence (ICIQ-UI), Quality-of-Life (QoL), IPSS, uroflow (Qmax) and Prostate Specific Antigen (PSA). Adverse-events were recorded and graded using the Clavien–Dindo Adverse-event (CD-AE) classification. No significant difference in median IPSS and quality of life improvement was observed at any follow-up point. PAE had significantly better IIEF-15 and ICIQ-UI outcomes than HoLEP at 1 and 3 months. HoLEP outperformed PAE in PSA reduction, Qmax, and post-void residual (PVR) improvement at 3 and 12-months. However, PAE had shorter hospital stays and avoided catheterization. No major adverse events (Clavien–Dindo ≥ grade 3) occurred in either group. In men with BPH and prostate sizes 80–250gm, PAE and HoLEP produce similar IPSS and QoL improvement at medium-term follow-up. PAE had better IIEF-15 and ICIQ-UI, in addition to the advantage of avoiding catheterization and reduced hospital stay. HoLEP performed better in PSA reduction, Qmax, and PVR improvement at 3 and 12 months. No serious adverse events occurred in either treatment group. Small sample size and short-term follow-up were important limitations.

World Journal of UrologyVol. 44(1)
University of Miami (US), Eye Centers Of Florida (US)
Openalex Percentile: Top 90%
Urinary Bladder and Prostate Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.