Corrosion Behavior of Ti–13Zr–13Nb Alloy Coated by Dip and Electrophoretic Deposition with YSZ/TiO2: A Comparative Investigation

The objective of this research was to examine the effects of YSZ/TiO2 composite coatings applied to the surface of Ti–13Zr–13Nb titanium alloy in order to improve its biocompatibility and functionality in the context of medical applications. Experimental evaluations of corrosion as well as the tape testing was conducted in this research endeavor on joint implant alloys composed of Ti–13Zr–13Nb and coated with YSZ/TiO2 nanoceramic. The parameters utilized in the electrophoretic deposition procedure were as follows: 60 V, 7 min, 15% concentration, and 400 degrees of grinding. The parameters of the dip coating conditions were as follows: 60°C temperature, 10 s of grinding time, 15% concentration, while 400 degrees. For analysis purposes, we employed high-resolution scanning electron microscopy (FE-SEM) images of the coated alloys. A comprehensive examination of the thickness and microstructure of the coated surfaces was performed by employing atomic force microscopy (AFM) and optical microscopy. The corrosion resistance of the titanium alloys with a top coating was evaluated using electrochemical techniques, namely cyclic polarization and polarizing (Tafel), in a body fluid simulator (SBF). In order to evaluate the adhesive strength of the coatings, a tape tester was employed. Using the subsequent values, the corrosion resistance of the coated Ti–13Zr–13Nb alloys was assessed: at 37°C, both coating alloys demonstrated enhanced resistance to corrosion in Ringer’s solution. In contrast, corrosion was observed to be slower in the Ti–13Zr–13Nb alloy coated via electrophoretic deposition than in the alloy coated via dip coating (8.282 × 10–8 vs. 2.166 × 10–7, respectively).

Authors

Institutions

Publication Details

Journal
Russian Journal of Applied Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1134/s1070427225100015
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion Behavior of Ti–13Zr–13Nb Alloy Coated by Dip and Electrophoretic Deposition with YSZ/TiO2: A Comparative Investigation

Makarim Hazim Abdulkareem, Marwan B. Hussein, Ali M. Mustafa
Russian Journal of Applied Chemistry
Bone Tissue Engineering Materials
article

Corrosion Behavior of Ti–13Zr–13Nb Alloy Coated by Dip and Electrophoretic Deposition with YSZ/TiO2: A Comparative Investigation

Makarim Hazim Abdulkareem, Marwan B. Hussein, Ali M. Mustafa
article en

Abstract

The objective of this research was to examine the effects of YSZ/TiO2 composite coatings applied to the surface of Ti–13Zr–13Nb titanium alloy in order to improve its biocompatibility and functionality in the context of medical applications. Experimental evaluations of corrosion as well as the tape testing was conducted in this research endeavor on joint implant alloys composed of Ti–13Zr–13Nb and coated with YSZ/TiO2 nanoceramic. The parameters utilized in the electrophoretic deposition procedure were as follows: 60 V, 7 min, 15% concentration, and 400 degrees of grinding. The parameters of the dip coating conditions were as follows: 60°C temperature, 10 s of grinding time, 15% concentration, while 400 degrees. For analysis purposes, we employed high-resolution scanning electron microscopy (FE-SEM) images of the coated alloys. A comprehensive examination of the thickness and microstructure of the coated surfaces was performed by employing atomic force microscopy (AFM) and optical microscopy. The corrosion resistance of the titanium alloys with a top coating was evaluated using electrochemical techniques, namely cyclic polarization and polarizing (Tafel), in a body fluid simulator (SBF). In order to evaluate the adhesive strength of the coatings, a tape tester was employed. Using the subsequent values, the corrosion resistance of the coated Ti–13Zr–13Nb alloys was assessed: at 37°C, both coating alloys demonstrated enhanced resistance to corrosion in Ringer’s solution. In contrast, corrosion was observed to be slower in the Ti–13Zr–13Nb alloy coated via electrophoretic deposition than in the alloy coated via dip coating (8.282 × 10–8 vs. 2.166 × 10–7, respectively).

Russian Journal of Applied ChemistryVol. 98(10)
University of Technology - Iraq (IQ)
Openalex Percentile: Top 40%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Corrosion Behavior of Ti–13Zr–13Nb Alloy Coated by Dip and Electrophoretic Deposition with YSZ/TiO2: A Comparative Investigation — Makarim Hazim Abdulkareem, Marwan B. Hussein, et al. · Russian Journal of Applied Chemistry (2025) | TGRS Research Map | TGRS