Permeation through thin polymer films at cryogenic temperatures

• Measured He permeability coefficients of BoPET, PEEK, PEI, and EVOH thin films from 190 – 30 K. • Measured H 2 permeability coefficients of PEEK between 210 – 30 K. • Permeability-temperature curves followed an Arrhenius relation. • Below 90 – 150 K, measured leak rates dropped below the detection limit of a calibrated mass spectrometer. • The above polymer films could serve as barrier membranes for liquid H 2 storage. Cryogenic propellant bladders could substantially improve propellant storage and slosh characteristics, especially in microgravity conditions. However, an experimental effort in the 1970s showed unacceptably high permeation rates of hydrogen and helium through thin polymer films (candidate materials for bladders) at cryogenic temperatures. A qualitative hypothesis for the increase is the relatively large thermal de Broglie wavelength of hydrogen and helium molecules at cryogenic temperatures could increase the hopping rate of the molecules and resulting bulk permeation. This hypothesis was tested by measuring the leak rate of helium through thin films (on the order of 25 µ m thick) of polyether ether ketone (PEEK), polyetherimide (PEI), ethylene vinyl alcohol (EVOH), and biaxially-oriented polyethylene terephthalate (BoPET) from 190 – 30 K. Hydrogen permeation was also tested through PEEK specimens from 210 – 30 K. A calibrated variable mass-spectrometer and custom sample test-cell and apparatus were utilized. The measurements indicate that permeation follows an Arrhenius relation with decreasing temperature until the limit of the sensor resolution was achieved below ∼90 K for He, and below ∼150 K for H 2 . The anomalous increase in permeability with reducing temperature observed in the historical 1970′s study was only reproduced with samples known to have developed leaks in the sealing. Thus, polymer films could be viable permeation barriers for liquid cryogens in aerospace applications, including bladders.

Authors

Institutions

Publication Details

Journal
Cryogenics
Published
2026-01-13
DOI
https://doi.org/10.1016/j.cryogenics.2026.104279
Primary Topic
Membrane Separation and Gas Transport
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Permeation through thin polymer films at cryogenic temperatures

Kjell Westra, Jacob Leachman
Cryogenics
Membrane Separation and Gas Transport
article

Permeation through thin polymer films at cryogenic temperatures

Kjell Westra, Jacob Leachman
article en

Abstract

• Measured He permeability coefficients of BoPET, PEEK, PEI, and EVOH thin films from 190 – 30 K. • Measured H 2 permeability coefficients of PEEK between 210 – 30 K. • Permeability-temperature curves followed an Arrhenius relation. • Below 90 – 150 K, measured leak rates dropped below the detection limit of a calibrated mass spectrometer. • The above polymer films could serve as barrier membranes for liquid H 2 storage. Cryogenic propellant bladders could substantially improve propellant storage and slosh characteristics, especially in microgravity conditions. However, an experimental effort in the 1970s showed unacceptably high permeation rates of hydrogen and helium through thin polymer films (candidate materials for bladders) at cryogenic temperatures. A qualitative hypothesis for the increase is the relatively large thermal de Broglie wavelength of hydrogen and helium molecules at cryogenic temperatures could increase the hopping rate of the molecules and resulting bulk permeation. This hypothesis was tested by measuring the leak rate of helium through thin films (on the order of 25 µ m thick) of polyether ether ketone (PEEK), polyetherimide (PEI), ethylene vinyl alcohol (EVOH), and biaxially-oriented polyethylene terephthalate (BoPET) from 190 – 30 K. Hydrogen permeation was also tested through PEEK specimens from 210 – 30 K. A calibrated variable mass-spectrometer and custom sample test-cell and apparatus were utilized. The measurements indicate that permeation follows an Arrhenius relation with decreasing temperature until the limit of the sensor resolution was achieved below ∼90 K for He, and below ∼150 K for H 2 . The anomalous increase in permeability with reducing temperature observed in the historical 1970′s study was only reproduced with samples known to have developed leaks in the sealing. Thus, polymer films could be viable permeation barriers for liquid cryogens in aerospace applications, including bladders.

CryogenicsVol. 155
Washington State University (US)
Openalex Percentile: Top 90%
Membrane Separation and Gas Transport
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Permeation through thin polymer films at cryogenic temperatures — Kjell Westra, Jacob Leachman · Cryogenics (2026) | TGRS Research Map | TGRS