Automated Detection of Normal, Atrial, and Ventricular Premature Beats from Single-Lead ECG Using Convolutional Neural Networks

Accurate detection of premature atrial contractions (PACs) and premature ventricular contractions (PVCs) in single-lead electrocardiograms (ECGs) is crucial for early identification of patients at risk for atrial fibrillation, cardiomyopathy, and other adverse outcomes. In this work, we present a fully convolutional one-dimensional U-Net that reframes beat classification as a segmentation task and directly detects normal beats, PACs, and PVCs from raw ECG signals. The architecture employs a ConvNeXt V2 encoder with simple decoder blocks and does not rely on explicit R-peak detection, handcrafted features, or fixed-length input windows. The model is trained on the Icentia11k database and an in-house single-lead ECG dataset that emphasizes challenging, noisy recordings, and is validated on the CPSC2020 database. Generalization is assessed across several benchmark and clinical datasets, including MIT-BIH Arrhythmia (ADB), MIT 11, AHA, NST, SVDB, CST STRIPS, and CPSC2020. The proposed method achieves near-perfect QRS detection (sensitivity and precision up to 0.999) and competitive PVC performance, with sensitivity ranging from 0.820 (AHA) to 0.986 (MIT 11) and precision up to 0.993 (MIT 11). PAC detection is more variable, with sensitivities between 0.539 and 0.797 and precisions between 0.751 and 0.910, yet the resulting F1-score of 0.72 on SVDB exceeds that of previously published approaches. Model interpretability is addressed using Layer-wise Gradient-weighted Class Activation Mapping (LayerGradCAM), which confirms physiologically plausible attention to QRS complexes for PVCs and to P-waves for PACs. Overall, the proposed framework provides a robust, interpretable, and hardware-efficient solution for joint PAC and PVC detection in noisy, single-lead ECG recordings, suitable for integration into Holter and wearable monitoring systems.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-12
DOI
https://doi.org/10.3390/s26020513
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated Detection of Normal, Atrial, and Ventricular Premature Beats from Single-Lead ECG Using Convolutional Neural Networks

Peter D. Rumm, Dimitri Kraft
Sensors
ECG Monitoring and Analysis
article

Automated Detection of Normal, Atrial, and Ventricular Premature Beats from Single-Lead ECG Using Convolutional Neural Networks

Peter D. Rumm, Dimitri Kraft
article en

Abstract

Accurate detection of premature atrial contractions (PACs) and premature ventricular contractions (PVCs) in single-lead electrocardiograms (ECGs) is crucial for early identification of patients at risk for atrial fibrillation, cardiomyopathy, and other adverse outcomes. In this work, we present a fully convolutional one-dimensional U-Net that reframes beat classification as a segmentation task and directly detects normal beats, PACs, and PVCs from raw ECG signals. The architecture employs a ConvNeXt V2 encoder with simple decoder blocks and does not rely on explicit R-peak detection, handcrafted features, or fixed-length input windows. The model is trained on the Icentia11k database and an in-house single-lead ECG dataset that emphasizes challenging, noisy recordings, and is validated on the CPSC2020 database. Generalization is assessed across several benchmark and clinical datasets, including MIT-BIH Arrhythmia (ADB), MIT 11, AHA, NST, SVDB, CST STRIPS, and CPSC2020. The proposed method achieves near-perfect QRS detection (sensitivity and precision up to 0.999) and competitive PVC performance, with sensitivity ranging from 0.820 (AHA) to 0.986 (MIT 11) and precision up to 0.993 (MIT 11). PAC detection is more variable, with sensitivities between 0.539 and 0.797 and precisions between 0.751 and 0.910, yet the resulting F1-score of 0.72 on SVDB exceeds that of previously published approaches. Model interpretability is addressed using Layer-wise Gradient-weighted Class Activation Mapping (LayerGradCAM), which confirms physiologically plausible attention to QRS complexes for PVCs and to P-waves for PACs. Overall, the proposed framework provides a robust, interpretable, and hardware-efficient solution for joint PAC and PVC detection in noisy, single-lead ECG recordings, suitable for integration into Holter and wearable monitoring systems.

SensorsVol. 26(2)
Medprevent Ottobrunn (DE)
Openalex Percentile: Top 91%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.