Diagnostic Accuracy of Physical Examination for Detecting Arteriovenous Fistula Stenosis in Haemodialysis Patients

OBJECTIVE: This study was conducted to determine the accuracy of physical examination in detecting arteriovenous fistula stenosis in patients receiving maintenance hemodialysis.METHODOLOGY: A cross-sectional study was undertaken from October 2021 to March 2022, encompassing both outpatient and inpatient units of Nephrology and Cardiothoracic Surgery at Shaikh Zayed Hospital (SKZ), Lahore.This study evaluated 162 maintenance hemodialysis (MHD) patients selected through convenience sampling for the Presence of arteriovenous fistula (AVF) stenosis.The data were collected after the MHD session.After collecting demographics, patients underwent physical examinations performed by a trained nephrology resident, followed by colour Doppler sonography (CDS) performed by a radiologist blinded to the results of the physical examination (PE) for AVF stenosis.Cohen's Kappa (), positive predictive values (PPV), negative predictive values (NPV), sensitivity, and specificity were used to calculate the accuracy of PE for AVF stenosis.RESULTS: There was a strong agreement between PE and CDS regarding the diagnosis of AVF stenosis.The overall diagnostic accuracy of physical examination to detect AVF stenosis was 89.50% with PPV= 88.5%, NPV=90.7%,sensitivity= 91.7%, specificity=87.2%,and = 0.790.The diagnostic accuracy of physical examination to detect AVF inflow stenosis was 89.473% with PPV= 87.2%, NPV=90.7%,sensitivity= 82.9%, specificity=93.2%,and = 0.769.The diagnostic accuracy of physical examination to detect AVF outflow stenosis was 90.243% with PPV= 89.6%, NPV=90.7%,sensitivity= 86.0%, specificity=93.2%,and = 0.797.CONCLUSION: The findings of this study demonstrate that PE examination is a reliable method for regularly monitoring AVF patency.

Publication Details

Journal
Journal of Liaquat University of Medical & Health Sciences
Published
2025-12-30
DOI
https://doi.org/10.22442/jlumhs.2025.01282
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Accuracy of Physical Examination for Detecting Arteriovenous Fistula Stenosis in Haemodialysis Patients

Journal of Liaquat University of Medical & Health Sciences
Central Venous Catheters and Hemodialysis
article

Diagnostic Accuracy of Physical Examination for Detecting Arteriovenous Fistula Stenosis in Haemodialysis Patients

article en

Abstract

OBJECTIVE: This study was conducted to determine the accuracy of physical examination in detecting arteriovenous fistula stenosis in patients receiving maintenance hemodialysis.METHODOLOGY: A cross-sectional study was undertaken from October 2021 to March 2022, encompassing both outpatient and inpatient units of Nephrology and Cardiothoracic Surgery at Shaikh Zayed Hospital (SKZ), Lahore.This study evaluated 162 maintenance hemodialysis (MHD) patients selected through convenience sampling for the Presence of arteriovenous fistula (AVF) stenosis.The data were collected after the MHD session.After collecting demographics, patients underwent physical examinations performed by a trained nephrology resident, followed by colour Doppler sonography (CDS) performed by a radiologist blinded to the results of the physical examination (PE) for AVF stenosis.Cohen's Kappa (), positive predictive values (PPV), negative predictive values (NPV), sensitivity, and specificity were used to calculate the accuracy of PE for AVF stenosis.RESULTS: There was a strong agreement between PE and CDS regarding the diagnosis of AVF stenosis.The overall diagnostic accuracy of physical examination to detect AVF stenosis was 89.50% with PPV= 88.5%, NPV=90.7%,sensitivity= 91.7%, specificity=87.2%,and = 0.790.The diagnostic accuracy of physical examination to detect AVF inflow stenosis was 89.473% with PPV= 87.2%, NPV=90.7%,sensitivity= 82.9%, specificity=93.2%,and = 0.769.The diagnostic accuracy of physical examination to detect AVF outflow stenosis was 90.243% with PPV= 89.6%, NPV=90.7%,sensitivity= 86.0%, specificity=93.2%,and = 0.797.CONCLUSION: The findings of this study demonstrate that PE examination is a reliable method for regularly monitoring AVF patency.

Journal of Liaquat University of Medical & Health SciencesVol. 24(04)
Good health and well-being
Openalex Percentile: Top 22%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Diagnostic Accuracy of Physical Examination for Detecting Arteriovenous Fistula Stenosis in Haemodialysis Patients · Journal of Liaquat University of Medical & Health Sciences (2025) | TGRS Research Map | TGRS