Research and application of a QCL Faraday rotation spectroscopy NO nonlinear inversion model based on machine learning

Aiming at the detection needs of the large range of NO concentration changes in mobile source exhaust, this study develops a machine-learning-based nonlinear concentration inversion model for QCL Faraday rotation spectroscopy. The model was trained using 44 spectra and evaluated through 40 runs, and the PSO strategy was compared with GWO, SA, and ACA, showing that the PSO achieved the best model performance with a correlation of 0.9983±0.0016, absolute error within ±20<i>p</i><i>p</i><i>m</i>, and relative error within 2%. Validation against a HORIBA OBS-ONE under RDE conditions showed high consistency, demonstrating that the proposed method enables accurate, sensitive, and wide-range NO measurements for mobile source emissions.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2026-01-12
DOI
https://doi.org/10.1364/ao.578674
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and application of a QCL Faraday rotation spectroscopy NO nonlinear inversion model based on machine learning

Boen Lei, Ying He, Kun You, Yujun Zhang et al.
Applied Optics
Water Quality Monitoring and Analysis
article

Research and application of a QCL Faraday rotation spectroscopy NO nonlinear inversion model based on machine learning

Boen Lei, Ying He, Kun You, Yujun Zhang, Feng Fan
article en

Abstract

Aiming at the detection needs of the large range of NO concentration changes in mobile source exhaust, this study develops a machine-learning-based nonlinear concentration inversion model for QCL Faraday rotation spectroscopy. The model was trained using 44 spectra and evaluated through 40 runs, and the PSO strategy was compared with GWO, SA, and ACA, showing that the PSO achieved the best model performance with a correlation of 0.9983±0.0016, absolute error within ±20<i>p</i><i>p</i><i>m</i>, and relative error within 2%. Validation against a HORIBA OBS-ONE under RDE conditions showed high consistency, demonstrating that the proposed method enables accurate, sensitive, and wide-range NO measurements for mobile source emissions.

Applied OpticsVol. 65(5)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN)
Openalex Percentile: Top 90%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies