The Accuracy of Maxillary Canines’ Rotation with Different Attachment Designs: A Retrospective Study

<b>Background/Objectives</b>: The rotation of maxillary canines represents one of the least predictable movements with clear aligners, particularly in cases requiring rotations greater than 10°, due to the rounded crown morphology and limited aligner grip. The aim of this retrospective study was to compare three different crescent-shaped attachment designs (vertical, horizontal, and oblique) for maxillary canine rotations greater than 10° with clear aligners. <b>Methods</b>: Seventy-eight maxillary canines were retrospectively selected and allocated into three equal groups (<i>n</i> = 26) according to the orientation of the applied attachment: vertical, horizontal, or oblique crescent-shaped attachments. Digital STL models (initial, predicted, and final) were imported into Dolphin 3D software 12.0.63 to assess the accuracy of maxillary canine's rotation through the comparison between planned and achieved values. <b>Results</b>: Mean rotational accuracy was 55.10% ± 15.60 for the vertical group, 62.40% ± 16.10 for the horizontal group, and 64.60% ± 19.40 for the oblique group. One-way ANOVA showed no statistically significant differences among groups (<i>p</i> = 0.09). Pairwise analysis revealed a statistically significant difference between the oblique and vertical designs (<i>p</i> = 0.05). <b>Conclusions</b>: Attachment orientation may influence the accuracy of maxillary canine rotation with clear aligners, with oblique crescent-shaped attachments showing a trend toward improved rotational control.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-01-13
DOI
https://doi.org/10.3390/jcm15020632
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Accuracy of Maxillary Canines’ Rotation with Different Attachment Designs: A Retrospective Study

Massimo Cordaro, Patrizia Gallenzi, Edoardo Staderini, Rosalba Diana et al.
Journal of Clinical Medicine
Orthodontics and Dentofacial Orthopedics
article

The Accuracy of Maxillary Canines’ Rotation with Different Attachment Designs: A Retrospective Study

Massimo Cordaro, Patrizia Gallenzi, Edoardo Staderini, Rosalba Diana, Federica Guglielmi, Licia Leccese, Michele Tepedino, Marianna Balacco, Anna Alessandri-Bonetti
article en

Abstract

<b>Background/Objectives</b>: The rotation of maxillary canines represents one of the least predictable movements with clear aligners, particularly in cases requiring rotations greater than 10°, due to the rounded crown morphology and limited aligner grip. The aim of this retrospective study was to compare three different crescent-shaped attachment designs (vertical, horizontal, and oblique) for maxillary canine rotations greater than 10° with clear aligners. <b>Methods</b>: Seventy-eight maxillary canines were retrospectively selected and allocated into three equal groups (<i>n</i> = 26) according to the orientation of the applied attachment: vertical, horizontal, or oblique crescent-shaped attachments. Digital STL models (initial, predicted, and final) were imported into Dolphin 3D software 12.0.63 to assess the accuracy of maxillary canine's rotation through the comparison between planned and achieved values. <b>Results</b>: Mean rotational accuracy was 55.10% ± 15.60 for the vertical group, 62.40% ± 16.10 for the horizontal group, and 64.60% ± 19.40 for the oblique group. One-way ANOVA showed no statistically significant differences among groups (<i>p</i> = 0.09). Pairwise analysis revealed a statistically significant difference between the oblique and vertical designs (<i>p</i> = 0.05). <b>Conclusions</b>: Attachment orientation may influence the accuracy of maxillary canine rotation with clear aligners, with oblique crescent-shaped attachments showing a trend toward improved rotational control.

Journal of Clinical MedicineVol. 15(2)
Università Cattolica del Sacro Cuore (IT), University of L'Aquila (IT), Agostino Gemelli University Polyclinic (IT), University of the Sacred Heart (JP)
Openalex Percentile: Top 88%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.