Measurement of a Flight-Like TES Microcalorimeter Array for the NewAthena X-IFU Development Model

The X-ray Integral Field Unit (X-IFU) on the NewAthena X-ray Observatory will fly a 1,504 pixel transitionedge sensor (TES) microcalorimeter array to study the Hot and Energetic X-ray Universe. For the first time, we have developed and measured a flight-like X-IFU detector that matches the pixel design and array configuration of the planned flight model, including the now baselined 50μm × 30μm TES pixels as well as flight-like electrical and mechanical wafer interfaces. This detector has undergone detailed characterization at NASA/GSFC in preparation to serve as the Development Model (DM) array for the X-IFU instrument. We measured roughly 150 pixels distributed across the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\sim 1.5$</tex-math></inline-formula> cm diameter hexagonal detector array to verify target adherence and spatial uniformity of key TES pixel parameters and performance metrics, including transition temperature, transition shape, normal-state resistance, conductance to thermal bath, complex impedance, and spectral resolution. The average spectral resolution at 6.9 keV is 2.01 ± 0.31 eV, or 1.93 ± 0.11 eV when removing 16 pixels with degraded performance from fabrication defects. For a smaller subset of pixels we also verified the pixel crosstalk and gain sensitivities meet requirements.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2026-01-12
DOI
https://doi.org/10.1109/tasc.2026.3652454
Citations
1
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
23.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of a Flight-Like TES Microcalorimeter Array for the NewAthena X-IFU Development Model

H. Muramatsu, Kazuhiro Sakai, N. DeNigris, R. L. Kelley et al.
1 citations
IEEE Transactions on Applied Superconductivity
Superconducting and THz Device Technology
23.83
article

Measurement of a Flight-Like TES Microcalorimeter Array for the NewAthena X-IFU Development Model

H. Muramatsu, Kazuhiro Sakai, N. DeNigris, R. L. Kelley, C. A. Kilbourne, R. B. Borrelli, C. V. Ambarish, S. H. Yoon, A. Rani, E. J. Wassell, F. M. Finkbeiner, J. S. Adams, S. J. Smith, F. A. Colazo Petit, J. D. Fuhrman, S. V. Hull, S. R. Bandler, F. S. Porter, N. A. Wakeham, T. Farrahi, J. A. Chervenak
article en
1 citations

Abstract

The X-ray Integral Field Unit (X-IFU) on the NewAthena X-ray Observatory will fly a 1,504 pixel transitionedge sensor (TES) microcalorimeter array to study the Hot and Energetic X-ray Universe. For the first time, we have developed and measured a flight-like X-IFU detector that matches the pixel design and array configuration of the planned flight model, including the now baselined 50μm × 30μm TES pixels as well as flight-like electrical and mechanical wafer interfaces. This detector has undergone detailed characterization at NASA/GSFC in preparation to serve as the Development Model (DM) array for the X-IFU instrument. We measured roughly 150 pixels distributed across the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\sim 1.5$</tex-math></inline-formula> cm diameter hexagonal detector array to verify target adherence and spatial uniformity of key TES pixel parameters and performance metrics, including transition temperature, transition shape, normal-state resistance, conductance to thermal bath, complex impedance, and spectral resolution. The average spectral resolution at 6.9 keV is 2.01 ± 0.31 eV, or 1.93 ± 0.11 eV when removing 16 pixels with degraded performance from fabrication defects. For a smaller subset of pixels we also verified the pixel crosstalk and gain sensitivities meet requirements.

IEEE Transactions on Applied SuperconductivityVol. 36(6)
Goddard Space Flight Center (US), University of America (US), Columbus Technologies and Services (United States) (US), Stinger Ghaffarian Technologies (United States) (US), Riverton Hospital (US), Barron Associates (United States) (US), Adnet Systems (United States) (US), University of Maryland, College Park (US), University of Maryland, Baltimore County (US), Catholic University of America (US)
Openalex Percentile: Top 2%
Superconducting and THz Device Technology
23.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.