Uncertainty Quantification in Hemodynamic Metrics from 4D Flow MRI with Super-resolution in a Carotid Bifurcation Model.

Super-resolution (SR) with supervised learning has emerged as a viable tool to enhance 4D flow magnetic resonance imaging (4DMR) data post hoc, but its impact on carotid hemodynamic measurements remains unclear. In this study, we quantified uncertainties in a phantom carotid artery model by comparing native 4DMR with and without SR against computational fluid dynamics (CFD) results. A phantom carotid artery model with steady flow was scanned at 3 Tesla. Magnitude images were segmented, and phase images were converted to velocities (3T). A pretrained 4DFlowNet was implemented to produce SR data (3T SR). A CFD simulation was performed on the same set up, serving as a reference. Uncertainties of geometrical processing were assessed by surface and Hausdorff distances. Hemodynamic metrics included intraluminal velocity and vorticity statistics, flow rate, and wall shear stress (WSS). A paired two-sided Wilcoxon signed-rank test was used to test the comparisons. Segmentations yielded a mean ± SD surface distance of 0.31 ± 0.06 mm (38 ± 7.5% of voxel size) and a Hausdorff distance of 1.2 mm. SR processing improved flow patterns and statistics of intraluminal hemodynamic parameters (p = 0.033). For flow rate, standard deviation decreased from 14.7% (3T) to 2.8% (3T SR), but mean values showed larger deviation after SR processing. Regarding WSS, qualitative improvements were observed, but quantitative comparisons did not show significant difference (p = 0.20). Our results suggest that SR processing stabilizes flow rate estimates and improves intraluminal hemodynamic statistics. But applying SR on data with inadequate quality may lead to larger errors. Further efforts are needed to improve generalizability.

Authors

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2026-01-07
DOI
https://doi.org/10.48620/93740
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty Quantification in Hemodynamic Metrics from 4D Flow MRI with Super-resolution in a Carotid Bifurcation Model.

B. Jung, Ali Mokhtari, Dominik Obrist, Andreas Harloff et al.
Open Access CRIS of the University of Bern
Advanced MRI Techniques and Applications
article

Uncertainty Quantification in Hemodynamic Metrics from 4D Flow MRI with Super-resolution in a Carotid Bifurcation Model.

B. Jung, Ali Mokhtari, Dominik Obrist, Andreas Harloff, Shaokai Zheng
article en

Abstract

Super-resolution (SR) with supervised learning has emerged as a viable tool to enhance 4D flow magnetic resonance imaging (4DMR) data post hoc, but its impact on carotid hemodynamic measurements remains unclear. In this study, we quantified uncertainties in a phantom carotid artery model by comparing native 4DMR with and without SR against computational fluid dynamics (CFD) results. A phantom carotid artery model with steady flow was scanned at 3 Tesla. Magnitude images were segmented, and phase images were converted to velocities (3T). A pretrained 4DFlowNet was implemented to produce SR data (3T SR). A CFD simulation was performed on the same set up, serving as a reference. Uncertainties of geometrical processing were assessed by surface and Hausdorff distances. Hemodynamic metrics included intraluminal velocity and vorticity statistics, flow rate, and wall shear stress (WSS). A paired two-sided Wilcoxon signed-rank test was used to test the comparisons. Segmentations yielded a mean ± SD surface distance of 0.31 ± 0.06 mm (38 ± 7.5% of voxel size) and a Hausdorff distance of 1.2 mm. SR processing improved flow patterns and statistics of intraluminal hemodynamic parameters (p = 0.033). For flow rate, standard deviation decreased from 14.7% (3T) to 2.8% (3T SR), but mean values showed larger deviation after SR processing. Regarding WSS, qualitative improvements were observed, but quantitative comparisons did not show significant difference (p = 0.20). Our results suggest that SR processing stabilizes flow rate estimates and improves intraluminal hemodynamic statistics. But applying SR on data with inadequate quality may lead to larger errors. Further efforts are needed to improve generalizability.

Open Access CRIS of the University of Bern
Society of Interventional Radiology (US)
Openalex Percentile: Top 91%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.