Performance Prediction for Counter-flow Desiccant Wheels Using an Approximate Solution

An analytical model has been developed to predict the performance of desiccant wheels. This model is based on an approximate solution derived from a set of linearized governing equations, with the assumption that the desiccant temperature and moisture concentration change over time according to trigonometric functions. The model predicts the outlet conditions of air streams in a silica gel desiccant wheel under typical operating conditions, and the results are compared with those obtained from a numerical model. It is found that the maximum absolute error is ±1.5 K in dry bulb temperature and ±0.6 g/kg in humidity ratio within the ranges of 0.5≤Cr≤1, 1≤Ntu<sub>0</sub>≤5, 10<sup>-2</sup>≤Cr*≤10.

Authors

Publication Details

Journal
Korean Journal of Air-Conditioning and Refrigeration Engineering
Published
2026-01-12
DOI
https://doi.org/10.6110/kjacr.2026.38.1.26
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Prediction for Counter-flow Desiccant Wheels Using an Approximate Solution

Dae-Young Lee, Dong-Seon Kim
Korean Journal of Air-Conditioning and Refrigeration Engineering
Adsorption and Cooling Systems
article

Performance Prediction for Counter-flow Desiccant Wheels Using an Approximate Solution

Dae-Young Lee, Dong-Seon Kim
article en

Abstract

An analytical model has been developed to predict the performance of desiccant wheels. This model is based on an approximate solution derived from a set of linearized governing equations, with the assumption that the desiccant temperature and moisture concentration change over time according to trigonometric functions. The model predicts the outlet conditions of air streams in a silica gel desiccant wheel under typical operating conditions, and the results are compared with those obtained from a numerical model. It is found that the maximum absolute error is ±1.5 K in dry bulb temperature and ±0.6 g/kg in humidity ratio within the ranges of 0.5≤Cr≤1, 1≤Ntu<sub>0</sub>≤5, 10<sup>-2</sup>≤Cr*≤10.

Korean Journal of Air-Conditioning and Refrigeration EngineeringVol. 38(1)
Openalex Percentile: Top 90%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.