Seismic performance of CFS–foamed concrete composite walls: Experimental investigation of the effects of flanges and dry connections

Although cold-formed steel (CFS) shear walls with infill materials have been widely investigated, experimental evidence on flanged, dry-assembled CFS–foam concrete composite shear walls (CFS-FCCWs) under cyclic loading remains critically limited—particularly with respect to the synergistic effects of cross-sectional geometry and connection detailing on failure mechanisms, ductility, and energy dissipation. To address this gap, this study presents a comprehensive experimental program involving six full-scale CFS-FCCW specimens subjected to quasi-static cyclic loading. The test matrix systematically varied two key parameters: (i) cross-sectional configuration (rectangular, T-shaped, and H-shaped) and (ii) dry connection type (web, end, and angle), all designed in compliance with GB/T 50011-2010. Results reveal that damage in flanged specimens primarily concentrated in the web region, characterized by a flexural-shear failure mechanism. The H-shaped configuration (CFS-FCCW-3) exhibited superior performance: peak load increased by 74.8% to 316.3 kN, and ductility coefficient improved by 30.5% to μ = 2.56 compared to the rectangular wall. In contrast, the T-shaped wall showed vulnerability at the free web end, with significantly enhanced performance under tensile flange loading—positive direction yielding 33.1% higher peak load and 23.0% greater ductility than the negative direction. All dry connections performed reliably without premature failure, confirming compliance with code provisions. Among them, the web connection underutilized adjacent materials; the end connection ensured structural integrity; and the angle connection demonstrated optimal energy dissipation capacity. Considering overall seismic resilience, constructability, and transport efficiency, the angle connection is recommended for practical implementation in prefabricated systems. Design recommendations are proposed to enhance the seismic behavior of flanged CFS-FCCWs, supporting the development of high-performance, modular structural solutions for seismic regions.

Authors

Institutions

Publication Details

Journal
Advances in Structural Engineering
Published
2026-01-12
DOI
https://doi.org/10.1177/13694332261415712
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic performance of CFS–foamed concrete composite walls: Experimental investigation of the effects of flanges and dry connections

Xiaomeng Ding, Zhiming Peng, Jiankang Lin, Zhongfan Chen et al.
Advances in Structural Engineering
Structural Load-Bearing Analysis
article

Seismic performance of CFS–foamed concrete composite walls: Experimental investigation of the effects of flanges and dry connections

Xiaomeng Ding, Zhiming Peng, Jiankang Lin, Zhongfan Chen, Zhifeng Xu
article en

Abstract

Although cold-formed steel (CFS) shear walls with infill materials have been widely investigated, experimental evidence on flanged, dry-assembled CFS–foam concrete composite shear walls (CFS-FCCWs) under cyclic loading remains critically limited—particularly with respect to the synergistic effects of cross-sectional geometry and connection detailing on failure mechanisms, ductility, and energy dissipation. To address this gap, this study presents a comprehensive experimental program involving six full-scale CFS-FCCW specimens subjected to quasi-static cyclic loading. The test matrix systematically varied two key parameters: (i) cross-sectional configuration (rectangular, T-shaped, and H-shaped) and (ii) dry connection type (web, end, and angle), all designed in compliance with GB/T 50011-2010. Results reveal that damage in flanged specimens primarily concentrated in the web region, characterized by a flexural-shear failure mechanism. The H-shaped configuration (CFS-FCCW-3) exhibited superior performance: peak load increased by 74.8% to 316.3 kN, and ductility coefficient improved by 30.5% to μ = 2.56 compared to the rectangular wall. In contrast, the T-shaped wall showed vulnerability at the free web end, with significantly enhanced performance under tensile flange loading—positive direction yielding 33.1% higher peak load and 23.0% greater ductility than the negative direction. All dry connections performed reliably without premature failure, confirming compliance with code provisions. Among them, the web connection underutilized adjacent materials; the end connection ensured structural integrity; and the angle connection demonstrated optimal energy dissipation capacity. Considering overall seismic resilience, constructability, and transport efficiency, the angle connection is recommended for practical implementation in prefabricated systems. Design recommendations are proposed to enhance the seismic behavior of flanged CFS-FCCWs, supporting the development of high-performance, modular structural solutions for seismic regions.

Advances in Structural Engineering
Shandong University of Science and Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 90%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.