Correlation between Ambient Air Temperature and Effective Bridge Temperature Based on Long-Term Field Monitoring: A Case Study of a Concrete Girder Bridge in South Africa

This study investigates the long-term thermal behavior of an RC twin spine-beam bridge, the Van Zylspruit Bridge, located in central South Africa. This research utilizes 9 years of field monitoring data, including over 11.5 million data points from 41 thermistors as well as local meteorological information, to establish appropriate design correlations between the environment and the bridge’s thermal response. This study found that the temperature specifications for both ambient air temperature (AAT) and effective bridge temperature (EBT) in the South African Bridge Code, TMH 7, were overly conservative for this specific bridge and location. For instance, the design 50-year return period minimum and maximum AAT corresponded to actual return periods of 3,675 and 595 years, respectively. Similarly, the design EBT limits showed significantly longer actual return periods. Ultimately, this study underscores the critical importance of using appropriate thermal material properties alongside locally relevant environmental data for thermal design of bridges and proposes an adapted method for determining design effective bridge temperatures based on local meteorological data.

Authors

Institutions

Publication Details

Journal
Journal of Bridge Engineering
Published
2026-01-12
DOI
https://doi.org/10.1061/jbenf2.beeng-7842
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation between Ambient Air Temperature and Effective Bridge Temperature Based on Long-Term Field Monitoring: A Case Study of a Concrete Girder Bridge in South Africa

S.A. Skorpen, E P Kearsley, J. Adendorff
Journal of Bridge Engineering
Structural Health Monitoring Techniques
article

Correlation between Ambient Air Temperature and Effective Bridge Temperature Based on Long-Term Field Monitoring: A Case Study of a Concrete Girder Bridge in South Africa

S.A. Skorpen, E P Kearsley, J. Adendorff
article en

Abstract

This study investigates the long-term thermal behavior of an RC twin spine-beam bridge, the Van Zylspruit Bridge, located in central South Africa. This research utilizes 9 years of field monitoring data, including over 11.5 million data points from 41 thermistors as well as local meteorological information, to establish appropriate design correlations between the environment and the bridge’s thermal response. This study found that the temperature specifications for both ambient air temperature (AAT) and effective bridge temperature (EBT) in the South African Bridge Code, TMH 7, were overly conservative for this specific bridge and location. For instance, the design 50-year return period minimum and maximum AAT corresponded to actual return periods of 3,675 and 595 years, respectively. Similarly, the design EBT limits showed significantly longer actual return periods. Ultimately, this study underscores the critical importance of using appropriate thermal material properties alongside locally relevant environmental data for thermal design of bridges and proposes an adapted method for determining design effective bridge temperatures based on local meteorological data.

Journal of Bridge EngineeringVol. 31(3)
University of Pretoria (ZA)
Openalex Percentile: Top 90%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.