An Angle Estimation Approach for Coherent FDA Radar Based on Transmit-Receive Sum and Difference Beamforming

This paper proposes a high-precision angle estimation method based on transmit sum and difference beamforming for coherent frequency diverse array (FDA) radar. By employing a small frequency offset across the array aperture, the coherent FDA radar achieves a range-angle-coupled transmit beampattern that combines wide transmission coverage with narrow reception capability. The proposed method constructs an equivalent two-dimensional coupled sum-difference beam in the target output channel by simultaneously utilizing signal detection outputs from multiple transmitted beams. This approach maintains the inherent advantages of FDA systems while enabling accurate angle estimation without sacrificing coverage. Simulation results demonstrate that the proposed architecture achieves an angular resolution of 1/20 of the beamwidth at a signal-to-noise ratio (SNR) of 20 dB, significantly outperforming conventional techniques. The method exhibits robust performance in various scenarios, which makes it a good candidate for modern radar applications requiring both wide-area surveillance and high-precision angle measurement.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-12
DOI
https://doi.org/10.3390/s26020487
Primary Topic
Radar Systems and Signal Processing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Angle Estimation Approach for Coherent FDA Radar Based on Transmit-Receive Sum and Difference Beamforming

Jingwei Xu, Jun Zhang, Guisheng Liao
Sensors
Radar Systems and Signal Processing
article

An Angle Estimation Approach for Coherent FDA Radar Based on Transmit-Receive Sum and Difference Beamforming

Jingwei Xu, Jun Zhang, Guisheng Liao
article en

Abstract

This paper proposes a high-precision angle estimation method based on transmit sum and difference beamforming for coherent frequency diverse array (FDA) radar. By employing a small frequency offset across the array aperture, the coherent FDA radar achieves a range-angle-coupled transmit beampattern that combines wide transmission coverage with narrow reception capability. The proposed method constructs an equivalent two-dimensional coupled sum-difference beam in the target output channel by simultaneously utilizing signal detection outputs from multiple transmitted beams. This approach maintains the inherent advantages of FDA systems while enabling accurate angle estimation without sacrificing coverage. Simulation results demonstrate that the proposed architecture achieves an angular resolution of 1/20 of the beamwidth at a signal-to-noise ratio (SNR) of 20 dB, significantly outperforming conventional techniques. The method exhibits robust performance in various scenarios, which makes it a good candidate for modern radar applications requiring both wide-area surveillance and high-precision angle measurement.

SensorsVol. 26(2)
Xidian University (CN), PLA Electronic Engineering Institute (CN)
Openalex Percentile: Top 93%
Radar Systems and Signal Processing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.