P-1032. Vein Attempts & IV League Hazards: Rethinking Peripheral IV and Bacteremia Risk

Abstract Background Peripheral intravenous catheters (PIV) are the most common invasive devices in hospitalized patients, yet data pertaining to serious complications from PIV are scarce. After noticing an apparent uptick in such complications, we sought to determine the frequency and impact of PIV-related bacteremia from 01/01/2023 to 04/15/2025 at a 528-bed teaching hospital in upstate New York.Table 1Characteristics of Peripheral Intravenous Catheter Associated Bacteremia (n = 28)Table 2Barriers to Best Practices for Insertion and Maintenance of Peripheral Intravenous Catheters Methods All blood cultures positive >/= 48 hrs. post admission were obtained via laboratory information system query. Number of PIV starts was obtained from census data. All patients with Staphlococcus aureus bacteremia (SaB) are routinely seen by infectious diseases providers who identify the source of all bacteremia. During mandatory reporting of hospital onset methicillin resistant SaB, the source of the bacteremia is also routinely identified. PIV-related adverse events were obtained from a virtual private network service (Safe Connect® McAfee) used to report serious safety-related issues, and via notifications from staff. Records of patients with proven PIV-driven bacteremia were retrospectively reviewed. Results 7477 PIV starts led to 28 bacteremias for a rate of 3.7 bacteremias/1,000 starts. 1534 positive blood cultures from 1017 unique patients were obtained. 2.8% (28/1017) of all hospital onset (HO) bacteremia had PIV as a definite source. Five species accounted for all PIV-driven bacteremia (PIV-B), 71% (n=20) were SaB (Table 1). 21% (6/28) of PIV-B were caused by MRSA. 25 HO-MRSA occurred. 24% 6/25 of HO MRSA had PIV as the source of the bacteremia. PIV-B was associated with the excess costs seen in Table 1, including a mean of 17.2 extra days of stay and 21.3 extra antibiotic days of therapy. PIV-B was also associated with endocarditis and central nervous system involvement. 21% of PIV-B were fatal. Conclusion The morbidity, mortality and avoidable costs associated with PIV-B are substantial. Our findings highlight the criticality of using well-known best practices for insertion and maintenance. Barriers to those practices appear in Table 2. Disclosures All Authors: No reported disclosures

Authors

Institutions

Publication Details

Journal
Open Forum Infectious Diseases
Published
2026-01-01
DOI
https://doi.org/10.1093/ofid/ofaf695.1228
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P-1032. Vein Attempts & IV League Hazards: Rethinking Peripheral IV and Bacteremia Risk

Jennifer Fede, Emil Lesho, Roopali Dahiya, Melissa Bonstein et al.
Open Forum Infectious Diseases
Central Venous Catheters and Hemodialysis
article

P-1032. Vein Attempts & IV League Hazards: Rethinking Peripheral IV and Bacteremia Risk

Jennifer Fede, Emil Lesho, Roopali Dahiya, Melissa Bonstein, Jennifer Gutowski, Kelly Cunningham
article en

Abstract

Abstract Background Peripheral intravenous catheters (PIV) are the most common invasive devices in hospitalized patients, yet data pertaining to serious complications from PIV are scarce. After noticing an apparent uptick in such complications, we sought to determine the frequency and impact of PIV-related bacteremia from 01/01/2023 to 04/15/2025 at a 528-bed teaching hospital in upstate New York.Table 1Characteristics of Peripheral Intravenous Catheter Associated Bacteremia (n = 28)Table 2Barriers to Best Practices for Insertion and Maintenance of Peripheral Intravenous Catheters Methods All blood cultures positive >/= 48 hrs. post admission were obtained via laboratory information system query. Number of PIV starts was obtained from census data. All patients with Staphlococcus aureus bacteremia (SaB) are routinely seen by infectious diseases providers who identify the source of all bacteremia. During mandatory reporting of hospital onset methicillin resistant SaB, the source of the bacteremia is also routinely identified. PIV-related adverse events were obtained from a virtual private network service (Safe Connect® McAfee) used to report serious safety-related issues, and via notifications from staff. Records of patients with proven PIV-driven bacteremia were retrospectively reviewed. Results 7477 PIV starts led to 28 bacteremias for a rate of 3.7 bacteremias/1,000 starts. 1534 positive blood cultures from 1017 unique patients were obtained. 2.8% (28/1017) of all hospital onset (HO) bacteremia had PIV as a definite source. Five species accounted for all PIV-driven bacteremia (PIV-B), 71% (n=20) were SaB (Table 1). 21% (6/28) of PIV-B were caused by MRSA. 25 HO-MRSA occurred. 24% 6/25 of HO MRSA had PIV as the source of the bacteremia. PIV-B was associated with the excess costs seen in Table 1, including a mean of 17.2 extra days of stay and 21.3 extra antibiotic days of therapy. PIV-B was also associated with endocarditis and central nervous system involvement. 21% of PIV-B were fatal. Conclusion The morbidity, mortality and avoidable costs associated with PIV-B are substantial. Our findings highlight the criticality of using well-known best practices for insertion and maintenance. Barriers to those practices appear in Table 2. Disclosures All Authors: No reported disclosures

Open Forum Infectious DiseasesVol. 13(Supplement_1)
Unity Health System (US), Rochester General Hospital (US)
Openalex Percentile: Top 92%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.