P-716. Limit of Detection and Inclusivity of a Research-Use-Only (RUO) Prototype of a Multiplexed Sample-to-Answer PCR System for the Identification of Vaginal Infections from Vaginal Swabs

Abstract Background Bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), and trichomoniasis, caused by Trichomonas vaginalis, are prevalent, symptomatically similar conditions causing vaginal discharge, discomfort, and adverse reproductive outcomes, if left untreated. bioMérieux is developing the BIOFIRE® SPOTFIRE® Vaginitis (VG) Panel, a syndromic, molecular test designed for the point-of-care setting to test a vaginal swab (Vswab) in eNAT® media, providing rapid diagnosis (≤ 20 minutes) for BV, VVC (specification of six Candida species), and trichomoniasis. These study results detail the limit of detection (LoD) and reactivity of the RUO Panel assays. Methods 95% LoD was determined for panel analytes using a dilution series of molecularly quantified strains in sample collection medium (eNAT) in the presence and absence of Vswab matrices. Ten unique Vswab samples were tested to evaluate the impact of matrix on the LoD of panel assays. Inclusivity was empirically assessed by testing 183 isolates, or synthetic nucleic acids (for unculturable or inaccessible analytes) at 3X – 10X LoD. Additionally, in silico assessments were performed to determine the reactivity of specific assay primers to > 3800 sequences representing agents of BV, VVC and trichomoniasis. Results The LoD ranged from 4.19E+01 to 5.93E+03 copies/mL for BV analytes, from 1.18E+02 to 1.05E+04 copies/mL for Candida species and 5.75E-01 copies/mL for T. vaginalis in Vswab. The LoD in Vswab was equal to or within 10X of eNAT demonstrating robust detection across multiple Vswab samples. See Table 1 for a summary of inclusivity. No limitation to reactivity was observed for 183/183 isolates tested. In silico analysis predicted 99.7% of available sequences to be reactive with panel assays. Conclusion These results indicate that the BIOFIRE® SPOTFIRE® VG Panel can correctly identify key pathogens implicated in vaginitis from vaginal swab samples with a high degree of accuracy. This abstract contains data regarding a device that has not been reviewed or approved by regulatory agencies for in vitro diagnostic use. Disclosures All Authors: No reported disclosures

Authors

Institutions

Publication Details

Journal
Open Forum Infectious Diseases
Published
2026-01-01
DOI
https://doi.org/10.1093/ofid/ofaf695.928
Primary Topic
Reproductive tract infections research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P-716. Limit of Detection and Inclusivity of a Research-Use-Only (RUO) Prototype of a Multiplexed Sample-to-Answer PCR System for the Identification of Vaginal Infections from Vaginal Swabs

Margarita B. Rogatcheva, Usha Spaulding, Robert C Trauscht, Brandon Hanberg et al.
Open Forum Infectious Diseases
Reproductive tract infections research
article

P-716. Limit of Detection and Inclusivity of a Research-Use-Only (RUO) Prototype of a Multiplexed Sample-to-Answer PCR System for the Identification of Vaginal Infections from Vaginal Swabs

Margarita B. Rogatcheva, Usha Spaulding, Robert C Trauscht, Brandon Hanberg, Ashley Hillman, Crystal Lederhos Smith, Craig K. Chandler, Michael G. Vaughn, Jessica Papenfuss, Justin Keener, Angela Clark, J Nicholas Francis
article en

Abstract

Abstract Background Bacterial vaginosis (BV), vulvovaginal candidiasis (VVC), and trichomoniasis, caused by Trichomonas vaginalis, are prevalent, symptomatically similar conditions causing vaginal discharge, discomfort, and adverse reproductive outcomes, if left untreated. bioMérieux is developing the BIOFIRE® SPOTFIRE® Vaginitis (VG) Panel, a syndromic, molecular test designed for the point-of-care setting to test a vaginal swab (Vswab) in eNAT® media, providing rapid diagnosis (≤ 20 minutes) for BV, VVC (specification of six Candida species), and trichomoniasis. These study results detail the limit of detection (LoD) and reactivity of the RUO Panel assays. Methods 95% LoD was determined for panel analytes using a dilution series of molecularly quantified strains in sample collection medium (eNAT) in the presence and absence of Vswab matrices. Ten unique Vswab samples were tested to evaluate the impact of matrix on the LoD of panel assays. Inclusivity was empirically assessed by testing 183 isolates, or synthetic nucleic acids (for unculturable or inaccessible analytes) at 3X – 10X LoD. Additionally, in silico assessments were performed to determine the reactivity of specific assay primers to > 3800 sequences representing agents of BV, VVC and trichomoniasis. Results The LoD ranged from 4.19E+01 to 5.93E+03 copies/mL for BV analytes, from 1.18E+02 to 1.05E+04 copies/mL for Candida species and 5.75E-01 copies/mL for T. vaginalis in Vswab. The LoD in Vswab was equal to or within 10X of eNAT demonstrating robust detection across multiple Vswab samples. See Table 1 for a summary of inclusivity. No limitation to reactivity was observed for 183/183 isolates tested. In silico analysis predicted 99.7% of available sequences to be reactive with panel assays. Conclusion These results indicate that the BIOFIRE® SPOTFIRE® VG Panel can correctly identify key pathogens implicated in vaginitis from vaginal swab samples with a high degree of accuracy. This abstract contains data regarding a device that has not been reviewed or approved by regulatory agencies for in vitro diagnostic use. Disclosures All Authors: No reported disclosures

Open Forum Infectious DiseasesVol. 13(Supplement_1)
bioMérieux (United States) (US)
Openalex Percentile: Top 91%
Reproductive tract infections research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies