Injectomat versus Infusomat in Day Surgery. A prospective, mixed-methods observational project, investigating which procedure is most sustainable

Background:Anaesthesia procedures can impact both environmental sustainability and the physical health of healthcare professionals.At Aarhus University hospitals Day Surgery Department,nurse anaesthetists reported finger pain and discomfort associated with frequent manual syringe preparation using injectomat.The aim was to compare the environmental impact,cost,and ergonomic workflow of two anaesthesia delivery procedures:injectomat (syringe pumps) or infusomat (drop counters). Method:We conducted a prospective,mixed-method observational study over 16 weeks,to investigate the difference of the two anaesthesia procedures.Anaesthesia nurse (n = 22) alternated between using injectomat and infusomat in two 8 week periods.Quantitative data were collected via daily utensil logs and the Disabilities of the arms,shoulders and hands questionnaire at weeks 1,4,and 8 of each period.Life Cycle Assessment was used to calculate the CO<sub>2e</sub> emissions of the utensils involved. Semi-structured interviews were conducted for qualitative insight. Results: Using infusomat reduced the daily amount of utensil used by 41,6%, resulting in a 13,6% cost reduction and a 33,42% decrease in CO<sub>2e</sub> emissions. Disabilities of the arms, shoulders and hands scores improved by 25,97% in week 1,12,8% in week 4, and 25% in week 8 during the infusomat period. Interviewed nurse anaesthetists reported significantly less strain on hands and fingers. Conclusion: Infusomat offer a more sustainable alternative to injectomat in anaesthesia for short procedures.They reduce utensil consumption, lower CO<sub>2e</sub> emissions, and improve nurse anaesthetists’ physical comfort. Further research is recommended in settings with longer procedures to assess generalizability and long-term effects.

Authors

Publication Details

Published
2025-12-01
Primary Topic
Climate Change and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Injectomat versus Infusomat in Day Surgery. A prospective, mixed-methods observational project, investigating which procedure is most sustainable

Ulla Madsen, Viktoria Reumert Laurberg, Line Agger Kolstrup, Jesper Skyttehave et al.
Climate Change and Health Impacts
article

Injectomat versus Infusomat in Day Surgery. A prospective, mixed-methods observational project, investigating which procedure is most sustainable

Ulla Madsen, Viktoria Reumert Laurberg, Line Agger Kolstrup, Jesper Skyttehave, Lise L. Nielsen, Freja M. Tække, Maria Gaden
article en

Abstract

Background:Anaesthesia procedures can impact both environmental sustainability and the physical health of healthcare professionals.At Aarhus University hospitals Day Surgery Department,nurse anaesthetists reported finger pain and discomfort associated with frequent manual syringe preparation using injectomat.The aim was to compare the environmental impact,cost,and ergonomic workflow of two anaesthesia delivery procedures:injectomat (syringe pumps) or infusomat (drop counters). Method:We conducted a prospective,mixed-method observational study over 16 weeks,to investigate the difference of the two anaesthesia procedures.Anaesthesia nurse (n = 22) alternated between using injectomat and infusomat in two 8 week periods.Quantitative data were collected via daily utensil logs and the Disabilities of the arms,shoulders and hands questionnaire at weeks 1,4,and 8 of each period.Life Cycle Assessment was used to calculate the CO<sub>2e</sub> emissions of the utensils involved. Semi-structured interviews were conducted for qualitative insight. Results: Using infusomat reduced the daily amount of utensil used by 41,6%, resulting in a 13,6% cost reduction and a 33,42% decrease in CO<sub>2e</sub> emissions. Disabilities of the arms, shoulders and hands scores improved by 25,97% in week 1,12,8% in week 4, and 25% in week 8 during the infusomat period. Interviewed nurse anaesthetists reported significantly less strain on hands and fingers. Conclusion: Infusomat offer a more sustainable alternative to injectomat in anaesthesia for short procedures.They reduce utensil consumption, lower CO<sub>2e</sub> emissions, and improve nurse anaesthetists’ physical comfort. Further research is recommended in settings with longer procedures to assess generalizability and long-term effects.

Responsible consumption and production
Openalex Percentile: Top 30%
Climate Change and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Injectomat versus Infusomat in Day Surgery. A prospective, mixed-methods observational project, investigating which procedure is most sustainable — Ulla Madsen, Viktoria Reumert Laurberg, et al. · (2025) | TGRS Research Map | TGRS