Application Research of Targeted Next-Generation Sequencing Technology Based on Bronchoalveolar Lavage Fluid in the Diagnosis of Pulmonary Tuberculosis and Drug-Resistance Detection
Chun-Yan Zhao,1,2,* Chang Song,1,2,* Xue-Wen Huang,1,2,* Ai-Chun Huang,1 Chun-Mei Zeng,1 Wei-Wen Li,1 Qiu-Qing Tan,1 Xiao-Shi Lin,2 Zhen-Tao Huang,2 Chang-Yue Jiang,3 Qing-Dong Zhu1 1Department of Tuberculosis, The Fourth People’s Hospital of Nanning, Nanning, Guangxi, 530023, People’s Republic of China; 2Clinical Medical School, Guangxi Medical University, Nanning, Guangxi, 530021, People’s Republic of China; 3Department of Pharmacy, The Fourth People’s Hospital of Nanning, Nanning, Guangxi, 530023, People’s Republic of China*These authors contributed equally to this workCorrespondence: Qing-Dong Zhu, Department of Tuberculosis, The Fourth People’s Hospital of Nanning, Nanning, Guangxi, 530023, People’s Republic of China, Email [email protected] Chang-Yue Jiang, Department of Pharmacy, The Fourth People’s Hospital of Nanning, Nanning, Guangxi, 530023, People’s Republic of China, Email [email protected]: To evaluate the clinical value of targeted next-generation sequencing (tNGS) using bronchoalveolar lavage fluid (BALF) in diagnosing pulmonary tuberculosis (PTB) and detecting resistance to first-line anti-tuberculosis drugs, and to compare its performance with traditional methods.Patients and Methods: In this study, BALF samples were collected from 258 patients with suspected PTB and subjected to AFB staining, mycobacterial solid culture, TB-DNA PCR, Xpert MTB/RIF, and tNGS. Using comprehensive clinical diagnosis or phenotypic DST as the reference, we evaluated the sensitivity, specificity, and other metrics of each method and assessed tNGS performance in detecting resistance to rifampicin, isoniazid, streptomycin, and ethambutol.Results: Overall, tNGS achieved a sensitivity of 91.10%, specificity of 89.70%, and an AUC of 0.904, all significantly higher than traditional methods. It uniquely identified 24 positive cases missed by other methods. In smear-negative patients, sensitivity remained high at 88.10%, with an AUC of 0.891. For drug-resistance detection, tNGS showed the best performance in judging isoniazid resistance (sensitivity 83.10%, specificity 90.30%), and also showed high negative predictive values for rifampicin, streptomycin, and ethambutol (all > 94%).Conclusion: tNGS provides excellent diagnostic accuracy for PTB and reliable detection of drug-resistant mutations from BALF samples. It is particularly suitable for smear-negative cases and for resistance screening, making it a powerful complement to the existing TB diagnosis system with high clinical application potential.Keywords: targeted next-generation sequencing, bronchoalveolar lavage, tuberculosis, drug resistance, diagnostic efficacy
Authors
- Huang AC
- Jiang CY
- Huang Zt
- Li WW
- Tan QQ
- Zeng CM
- Huang XW
- Zhao CY
- Song C
- Lin XS
- Zhu QD
Institutions
- School of Clinical Research (US)
Publication Details
- Journal
- SHILAP Revista de lepidopterología
- Published
- 2026-01-01
- Primary Topic
- Tuberculosis Research and Epidemiology
- Type
- article
- Field-Weighted Citation Impact
- 0.00