Experimental investigation on low-frequency vibration-assisted cutting of calcified tissue during rotational atherectomy

Rotational atherectomy (RA) is an effective minimally invasive treatment for severe coronary calcification, but it carries risks of vessel injury due to high mechanical and thermal loads. This study proposes a low-frequency vibration-assisted rotational atherectomy (LFVARA) technique that reduces cutting force and temperature rise by promoting cyclic disengagement between the tool and tissues. Experimental trials compared LFVARA against RA using bone cement as a calcified plaque phantom, with vibration parameters systematically varied across amplitudes (20–50 μm), frequencies (50–150 Hz), and rotational speeds (60000–120000 r/min). Response surface methodology based on a Box-Behnken design is employed to analyze parameter interactions and identify optimal conditions. Results show that increasing vibration frequency from 50 to 150 Hz at 50 μm amplitude prolongs non-cutting time per cycle by 19.47%, while raising rotational speed from 60000 to 120000 r/min at 50 μm/150 Hz reduces it by 26.59%. Under 120000 r/min/150 Hz/50 μm conditions, LFVARA mitigates mean cutting force by 23.85% and temperature rise by 29.24%, as validated by force-thermal metrics. The optimized parameter set (60000 r/min, 141.6 Hz, 49 μm) is experimentally validated with less than 10% error in force and 5% in temperature prediction. The findings demonstrate that LFVARA can effectively reduce the average cutting force and temperature rise during the process of removing calcified tissues. This work presents a promising approach for coronary atherosclerosis treatment, offering a novel method to optimize therapeutic efficacy.

Authors

Institutions

Publication Details

Journal
Chinese Journal of Mechanical Engineering
Published
2026-01-01
DOI
https://doi.org/10.1016/j.cjme.2026.100215
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on low-frequency vibration-assisted cutting of calcified tissue during rotational atherectomy

Zirui Huang, Bingwei He, Chuhang Gao, Xiang Lin et al.
Chinese Journal of Mechanical Engineering
Coronary Interventions and Diagnostics
article

Experimental investigation on low-frequency vibration-assisted cutting of calcified tissue during rotational atherectomy

Zirui Huang, Bingwei He, Chuhang Gao, Xiang Lin, Mingcheng Fang, Zhaoju Zhu, Yiping Huang
article en

Abstract

Rotational atherectomy (RA) is an effective minimally invasive treatment for severe coronary calcification, but it carries risks of vessel injury due to high mechanical and thermal loads. This study proposes a low-frequency vibration-assisted rotational atherectomy (LFVARA) technique that reduces cutting force and temperature rise by promoting cyclic disengagement between the tool and tissues. Experimental trials compared LFVARA against RA using bone cement as a calcified plaque phantom, with vibration parameters systematically varied across amplitudes (20–50 μm), frequencies (50–150 Hz), and rotational speeds (60000–120000 r/min). Response surface methodology based on a Box-Behnken design is employed to analyze parameter interactions and identify optimal conditions. Results show that increasing vibration frequency from 50 to 150 Hz at 50 μm amplitude prolongs non-cutting time per cycle by 19.47%, while raising rotational speed from 60000 to 120000 r/min at 50 μm/150 Hz reduces it by 26.59%. Under 120000 r/min/150 Hz/50 μm conditions, LFVARA mitigates mean cutting force by 23.85% and temperature rise by 29.24%, as validated by force-thermal metrics. The optimized parameter set (60000 r/min, 141.6 Hz, 49 μm) is experimentally validated with less than 10% error in force and 5% in temperature prediction. The findings demonstrate that LFVARA can effectively reduce the average cutting force and temperature rise during the process of removing calcified tissues. This work presents a promising approach for coronary atherosclerosis treatment, offering a novel method to optimize therapeutic efficacy.

Chinese Journal of Mechanical Engineering
Fuzhou University (CN), South China University of Technology (CN)
Openalex Percentile: Top 92%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.