A Physics-Based Framework for Accurate On-Farm Enteric Methane Sensing

The accuracy of on-farm sensors remains a limiting factor in their use to verify efforts to reduce enteric methane emissions. These “sniffers”, although scalable, measure gas concentration (ppm), which is poorly correlated with mass flux (g/day), because the dilution of enteric methane by turbulence is unmeasured. We develop a multiphysics framework that provides the first mechanistic connection from the biological source to the sensor reading. Our model combines a physiological mass balance of rumen gas production and mixing with a transient, buoyant puff model that captures the fluid dynamics of the emission event as it disperses into the near-field environment. Validated against field measurements of mass flux from emission events (a 9% error in mass prediction and a root-mean-square error of 0.4 mg/s), the model replicates the magnitude, fluctuations, and overall dispersion of mass flux using basic physiological variables and quantifies the “captured fraction” of mass by the device. This framework is a foundational tool for transforming low-cost sensor data into accurate measures of mass emission fluxes.

Authors

Institutions

Publication Details

Journal
ACS Agricultural Science & Technology
Published
2026-01-09
DOI
https://doi.org/10.1021/acsagscitech.5c00958
Primary Topic
Odor and Emission Control Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Physics-Based Framework for Accurate On-Farm Enteric Methane Sensing

Andrés Jaramillo-Botero, Diego F. Muriel
ACS Agricultural Science & Technology
Odor and Emission Control Technologies
article

A Physics-Based Framework for Accurate On-Farm Enteric Methane Sensing

Andrés Jaramillo-Botero, Diego F. Muriel
article en

Abstract

The accuracy of on-farm sensors remains a limiting factor in their use to verify efforts to reduce enteric methane emissions. These “sniffers”, although scalable, measure gas concentration (ppm), which is poorly correlated with mass flux (g/day), because the dilution of enteric methane by turbulence is unmeasured. We develop a multiphysics framework that provides the first mechanistic connection from the biological source to the sensor reading. Our model combines a physiological mass balance of rumen gas production and mixing with a transient, buoyant puff model that captures the fluid dynamics of the emission event as it disperses into the near-field environment. Validated against field measurements of mass flux from emission events (a 9% error in mass prediction and a root-mean-square error of 0.4 mg/s), the model replicates the magnitude, fluctuations, and overall dispersion of mass flux using basic physiological variables and quantifies the “captured fraction” of mass by the device. This framework is a foundational tool for transforming low-cost sensor data into accurate measures of mass emission fluxes.

ACS Agricultural Science & TechnologyVol. 6(2)
California Institute of Technology (US), Institute of Materials, Minerals and Mining (GB), Pontificia Universidad Javeriana (CO)
Openalex Percentile: Top 92%
Odor and Emission Control Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Physics-Based Framework for Accurate On-Farm Enteric Methane Sensing — Andrés Jaramillo-Botero, Diego F. Muriel · ACS Agricultural Science & Technology (2026) | TGRS Research Map | TGRS